Dacor RV46 Installation Instructions - Page 17

Technical Data - motor

Page 17 highlights

Technical Data RV Raised Vent Wiring Diagram LOWER LIMIT SWITCH COM NO UPPER LIMIT SWITCH COM NO TO PUSH BUTTON CIRCUIT BOARD POWER CONTROL CIRCUIT BOARD FUSE 12A BLOWR OUTPUT N2 L2 BLU GRN/YEL BLK WHT CHASSIS GROUND STUD INCOMING 120V N1 L1 MOTOR DRIVE L3 UPPER LIMIT SWITCH LOWER LIMIT SWITCH COM N3 BLK BLK RED BLU WHT CABP3 Cabinet Blower Ratings CABP3 Cabinet blower Airflow* Nominal 600 CFM Actual 585.6 CFM * At zero inches static pressure Electrical Rating: 4 Amps. @ 120 Vac, 60 Hz. For ILHSF or REMP series blower ratings, see the blower installation instructions. Static pressure - inches of water L2 N2 L1 N1 GND GND BLOWER OUTPUT POWER INPUT GROUND CABP3 Blower Performance 5.0 4.0 3.0 2.0 1.0 0 100 200 300 400 500 600 Airflow CFM (Cubic feet/minute) 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

15
Technical Data
CABP3 Cabinet blower Airflow*
Nominal
600 CFM
Actual
585.6 CFM
*
At zero inches static pressure
Electrical Rating: 4 Amps. @ 120 Vac, 60 Hz.
For ILHSF or REMP series blower ratings, see the blower
installation instructions.
CABP3 Cabinet Blower Ratings
RV Raised Vent Wiring Diagram
Airflow CFM (Cubic feet/minute)
Static pressure - inches of water
0
1.0
2.0
3.0
4.0
5.0
100
200
300
400
500
600
CABP3 Blower Performance
POWER CONTROL
CIRCUIT BOARD
TO PUSH
BUTTON CIRCUIT
BOARD
POWER
INPUT
GROUND
CHASSIS
GROUND
STUD
BLOWER
OUTPUT
UPPER
LIMIT SWITCH
LOWER
LIMIT SWITCH
MOTOR DRIVE
INCOMING
120V
BLOWR
OUTPUT
FUSE 12A
UPPER LIMIT SWITCH
COM
COM
COM
NO
NO
LOWER LIMIT SWITCH
BLK
BLK
RED
BLU
BLU
GRN/YEL
WHT
WHT
BLK
N3
L3
L2
N2
L2
N2
L1
N1
L1
N1
GND
GND