Dell Force10 S5000 Installation Guide - Page 12
Utility Panel, Power Supplies, Fans
View all Dell Force10 S5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Utility Panel The Utility panel side of the platform contains the fan and power modules. Figure 3. S5000 Power Supplies and Fan Modules 1. Slot 0 (for PSU 0) 2. Slot 1 (for Fan Module 0) 3. Slot 2 (for Fan Module 1) 4. Slot 3 (for PSU 1) 5. Grab Handles Power Supplies The S5000 supports two hot-swappable PSUs. NOTE: The PSUs must be installed at the customer site. The S5000 has SKUs that support the following configurations: • AC PSU with fan airflow from I/O to Utility • AC-R PSU with fan airflow from Utility to I/O • DC PSU with fan airflow from I/O to Utility • DC-R PSU with fan airflow from Utility to I/O PSUs are field replaceable. To ensure power redundancy and adequate cooling, install two power supplies in the switch. When running with full redundancy (two PSUs installed and running), you can remove and replace one PSU while the other PSU is running without disrupting traffic. Fans The S5000 supports two fan trays with airflow directions from I/O to Utility or Utility to I/O. Do not mix I/O to Utility and Utility to I/O airflows in a single S5000 chassis. All fans and PSUs in a configuration must be in the same airflow direction. If you create a mixed airflow configuration, the software notifies you of the invalid configuration. The fans must be installed at the customer site. 12