- Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 1
Dell™ Console Switch Console Switch Installer/User's Guide Model: Console Switch www.dell.com | support.dell.com - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 2
for energy efficiency. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own. Model Console Switch October 2004 - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 3
7 SIP Intelligent Module 7 Multiplatform Support 8 OSCAR Graphical User Interface 8 Security 8 Video 8 Plug and Play 8 FLASH Upgradable 9 Tiering Expansion 9 Safety Precautions 9 General 10 Rack Mounting of Systems 11 2 Installation Getting Started 13 Supplied with the Console Switch - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 4
to Servers 44 Changing Your Switch Mode (16-port Console Switch Only 46 A Appendices Appendix A: Flash Upgrades 49 Upgrading the Console Switch 49 Items Needed for the Upgrade 49 Upgrading Firmware 49 Upgrading the SIP 51 Appendix B: Technical Specifications 54 Appendix C: Notifications 56 - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 5
9 OU Mounting Bracket Installation 14 1U Installation 16 Basic Console Switch Configuration 17 Console Switch Configuration with a Tiered Switch . . . 19 Console Switch Configuration with a Legacy KVM Switch 21 Main Dialog Box 24 Setup Dialog Box 28 Names Dialog Box 29 Name Modify Dialog - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 6
Box 53 SIP Resolution and Refresh Rates 8 Legacy Switch Support 20 OSCAR Interface Status Symbols 24 OSCAR Interface Navigation Basics 26 Setup Features to Manage Routine Tasks for Your Servers 27 OSCAR Status Flags 33 Diagnostic Test Details 43 Technical Specifications 54 6 Contents - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 7
-port Dell™ Console Switches integrate keyboard, video, and mouse (KVM) switching technology with advanced cable management, flexible access for up to two simultaneous users, and an intuitive user interface. The Console Switch features powerful on-screen management for easy system configuration and - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 8
www.dell.com | support.dell.com Multiplatform Support The SIPs available with your Console Switch support PS/2 and USB server environments. PS/2, USB, Sun, and serial cabling options are also available using Avocent™ AVRIQ intelligent cables. Using the On-Screen Configuration and Activity Reporting - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 9
See "Tiering Console Switches" for more information. Figure 1-2. Example of a Console Switch Configuration Legacy Switch (tiered) Console Switch (tiered) Rack of Servers SIP Module Critical Server Analog Connection Analog Connection Console Switch (main) Safety Precautions Use the following - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 10
document pertains only to the Dell Console Switch. General • Observe and follow service markings: • Do not service any product except as explained , see the appropriate section in your troubleshooting guide or contact your trained service provider. • Use the product only with approved equipment. - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 11
use a surge suppressor, line conditioner, or uninterruptible power supply (UPS). • Position system cables and power cables carefully. Route cables a rack by trained service technicians. If a nonDell rack is utilized, be sure that the rack meets the specifications of a Dell rack. • Elevated Ambient - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 12
www.dell.com | support.dell.com 12 Product Overview - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 13
mounting bracket • One serial cable • Console Switch Installer/User's Guide • Console Switch Quick Installation Guide Additional Items Needed The following are additional items you may need to install your Console Switch: • One Server Interface Pod (SIP) module and UTP cabling per attached server or - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 14
www.dell.com | support.dell.com CAUTION: Before installing systems in a rack, install front install the 0U switch mounting bracket (shipped as default): 1 Line up the holes of the mounting brackets with the screw holes in the switch. 2 Fasten the mounting bracket to the switch using the button head - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 15
3 Line up the screw holes in the bracket with the screw holes in the switch. 4 With a Phillips screwdriver, fasten the front mounting brackets to the switch using two screws on each side. 5 Attach four cage nuts or clip nuts to the rack mounting flange of the rack cabinet's front so that the - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 16
www.dell.com | support.dell.com Figure 2-2. 1U Installation Installing the Console Switch Plug the supplied power cord into the back of the appliance and then into an appropriate power source. Figure 2-3 illustrates one possible configuration for your Console Switch. See the following detailed set - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 17
Figure 2-3. Basic Console Switch Configuration Local User B (16-port model only) Configuration Port (for updating firmware) Console Switch Local User A SIP Servers 2-16 Server 1 To connect a SIP to each server: 1 Locate the SIPs for your Console Switch. 2 Attach the appropriately cable ends to - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 18
up to 15 primary servers and 16 secondary servers. Using this configuration, you can tier 16 Console Switches under the main switch, enabling the connection of up to 256 servers. Only one level of tiering is supported in this type of configuration, which means that you cannot tier additional legacy - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 19
Figure 2-4. Console Switch Configuration with a Tiered Switch Local user A Local User B (16 port model only) Console Switch Tiered (secondary) Console Switch ARI Ports Primary Servers Secondary Servers Installation 19 - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 20
into your existing configuration. In a tiered system, each ARI port will accommodate up to 24 servers. See the following table for legacy switches compatible with the Console Switch system. Table 2-1. Legacy Switch Support Legacy Product Avocent switches Dell switches Model Numbers AV200 - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 21
Console Switch Configuration with a Legacy KVM Switch Local User Console Switch SIP PS/2 or USB or AVRIQ PS/2, USB, Sun, or Serial SIP Legacy Switch Legacy Switch Server 1 Server 2 To add a legacy KVM switch: 1 Mount the KVM switch into your rack cabinet. Locate a length of CAT 5 cabling - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 22
label the cables for easy identification. Setting Up Your Console Switch System With the Console Switch system, you can auto detect and configure each port on your appliance. "Basic Operation" provides detailed instructions on naming, customization, and OSCAR interface setup and configuration. 22 - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 23
and Servers Use the OSCAR Main dialog box to view, configure and control servers in the Console Switch system. View your servers by name, port or the unique Electronic ID (EID) number embedded in each Server Interface Pod (SIP). You will see an OSCAR interface-generated port list by default when you - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 24
www.dell.com | support.dell.com Figure 3-1. Main Dialog Box NOTE: You can also press the key twice within one second to launch the OSCAR interface. You can use this key sequence in any place you see throughout this installer/user's guide. Viewing the Status of Your Switch - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 25
. This leaves the user in a free state, with no server selected. The status flag on your desktop displays Free. NOTE: To clear all offline Server Interface Pods (SIPs) from the list, click Clear. Soft Switching Soft switching is the ability to switch servers using a hotkey sequence. You can - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 26
dell.com | support.dell.com 2 Click Setup - Menu. The Menu dialog box appears. 3 Set a Screen Delay Time by typing the number of seconds of delay you want between being pressed and the Main dialog box displaying. 4 Click OK. To soft switch executes actions when used with underlined or - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 27
or bottom of a list. Delete Deletes characters in a text box. Numbers Type from the keyboard or keypad. Configuring OSCAR Interface Menus You can configure your Console Switch from the Setup dialog box in OSCAR. Click the Names button when initially setting up your appliance to identify servers - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 28
3-2. Setup Dialog Box Assigning Server Names Use the Names dialog box to identify individual servers by name rather than by port number. The Names list is always sorted by port order. Names are stored in the SIP, so even if you move the cable/server to another ARI port, the name and configuration - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 29
Figure 3-3. Names Dialog Box NOTE: If the server list changes, the mouse cursor turns into an hourglass as the list is automatically updated. No mouse or keyboard input is accepted until the list update is complete. To assign names to servers: 1 In the Names dialog box, select a server name or port - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 30
X or press to exit the dialog box without saving changes. NOTE: If a SIP has not been assigned a name, the EID is used as the default name. Assigning Device Types While the appliance automatically discovers legacy KVM switches, you will need to specify the number of ports on the legacy - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 31
Figure 3-6. Device Modify Dialog Box 3 Choose the number of ports supported by your legacy switch and click OK. 4 Repeat steps 1 to 3 for each port requiring a device type to be assigned. 5 Click OK in the Devices dialog box to save settings. - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 32
interface displaying. To perform a soft switch, see "Soft Switching". Controlling the Status Flag The status flag displays on your desktop and shows the name or EID number of the selected server or the status of the selected port. Use the Flag dialog box to configure the flag to display by server - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 33
user has been disconnected from all systems Flag indicating that Broadcast mode is enabled To access the Flag dialog box: 1 Press . The Main dialog box appears. 2 Click Setup Timed to display the flag for only five seconds after switching. 3 Select a flag color in Display Color. 4 - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 34
local user port console. You can establish a screen saver mode that engages after your console remains unused for a specified Inactivity Time. Once engaged, your console will remain locked until you press any key or move the mouse. You will then need to type in your password to continue. Use the - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 35
, and then close the dialog box. NOTE: If you should lose or forget your password, you must return your switch for service or technical support. To password protect your console: 1 Set your password as described in the previous procedure. 2 Select Enable Screen Saver. 3 Type the number of minutes - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 36
. Displaying Version Information The OSCAR interface enables you to display the versions of the Console Switch and the SIP firmware. For optimum performance, keep your firmware current. For more information, see "Appendix A: Flash Upgrades". To display version information: 1 Press - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 37
Dialog Box 3 Click SIP to view individual SIP version information.The SIP Selection dialog box appears. Figure 3-12. SIP Selection Dialog Box 4 Select a SIP to view and click the Version button. The SIP Version dialog box appears. For more information on loading firmware, see "Appendix A: Flash - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 38
www.dell.com | support.dell.com Figure 3-13. SIP Version Dialog Box 5 Click X to close the SIP Version dialog box. Resetting a SIP PS/2 SIPs can be reset using the Reset button in the SIP Version dialog box. NOTE: This procedure is only relevant where your Console Switch system involves a PS/2 SIP - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 39
. A warning message appears, warning that the function is for tiered switches only and that resetting the SIP could result in the need to reboot the target server. 6 Click OK to proceed with the reset. or 7 Press to exit. Resetting Your Keyboard and Mouse If a keyboard or mouse locks up, you - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 40
www.dell.com | support.dell.com Figure 3-15. Commands Dialog Box Scanning Your System In scan mode, the appliance automatically scans from 1 If the OSCAR interface is not open, press . The Main dialog box appears. 2 Click Setup - Scan. The Scan dialog box appears. 40 Basic Operation - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 41
Figure 3-16. Scan Dialog Box 3 The dialog box contains a listing of all servers attached to your appliance. Click the check box next to the servers you wish to scan. -orDouble-click on a server's name or port. -orPress and the number of the server you wish to scan. You can select up to 16 - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 42
dell.com | support.dell functional sub-systems (memory, communications, switch control and the video channels) for option, you will receive a warning indicating that all users (remote and local) will be disconnected. Click OK SIPs into three categories: On-line, Offline or Suspect. 42 Basic Operation - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 43
Firmware CRCs Validates the current firmware images stored in the system's FLASH Comm Interfaces Validates internal communication pathways Switch Controller test Verifies the switch matrix controller is accessible and functional On-line SIPs all users will be disconnected. Basic Operation 43 - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 44
www.dell.com | support.dell.com Figure 3-19. Diagnostics Warning Message Box 3 Click OK to begin diagnostics. -orClick X or press to exit the dialog box without running a diagnostic test. 4 All users are disconnected and the Diagnostics dialog box displays. 5 As each test is finished, a - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 45
a broadcast to interpret keystrokes identically. Specifically, the and - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 46
www.dell.com | support.dell.com Figure 3-21. Broadcast Enable Dialog Box 5 Click OK to Your Switch Mode (16-port Console Switch Only) Your Console Switch allows you to connect to attached servers using two methods: Preemptive and Cooperative. Select Preemptive (default setting) to allow any user - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 47
Figure 3-22. Switch Dialog Box 3 Select either Preemptive or Cooperative as your switch mode. Basic Operation 47 - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 48
www.dell.com | support.dell.com 48 Basic Operation - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 49
Appendix A: Flash Upgrades Upgrading the Console Switch You can upgrade the firmware of your Console Switch by using a special update utility provided by Dell. This utility automatically configures the port communications settings to allow direct downloading from the connected server. Items Needed - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 50
www.dell.com | support.dell.com Possible Error Conditions If the download does not execute properly, verify the following: • Verify that the COM port is correct. • Verify that no other program is currently using the COM port, or that a previous DOS window/shell is open that had used the desired COM - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 51
: Do not cycle power to the server or disconnect the SIP during this process. A loss of power will render the SIP inoperable and require the unit be returned to the factory for repair. To simultaneously upgrade multiple SIPs: 1 Press . The Main dialog box appears. 2 Click Commands - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 52
www.dell.com | support.dell.com To upgrade SIP firmware individually: 1 Press . The Main dialog box appears. 2 Click Commands-Display Versions. The Version dialog box appears. Figure 4-3. Version Dialog Box 3 Click SIP to view individual SIP version information. Figure 4-4. SIP - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 53
Box 5 Click the Load Firmware button. The SIP Load dialog box appears. Figure 4-6. SIP Load Dialog Box 6 Click OK to initiate the upgrade and return to the SIP Status dialog box. NOTE: During an upgrade, the SIP status indicator in the Main dialog box will be yellow. The SIP is unavailable while an - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 54
www.dell.com | support.dell.com Appendix B: Technical Specifications Table 4-1. Technical Specifications Server Ports Number SIP Types Connectors Sync Types Plug and Play Video Resolution Update Port Number Type Analog Port Number Type Connectors Dimensions Dimensions (H x W x D) Weight Heat - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 55
Table 4-1. Technical Specifications (continued) Humidity 20 to 80% noncondensing operating 5 to 95% noncondensing nonoperating Appendices 55 - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 56
when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 57
Agency Approvals UL/cUL (UL 60950/CSA 22.2 No. 60950:2000) ICES-003 NOM-019-SCFI-1993 IRAM S Mark (Resolution 92/98) ACA AS/NZS 55022, class A CNS 13438 FCC Class A, EN60950:2000, EN55022:1998, EN55024:1998, EN61000-3-3:1995 +A1,A2. GS GOST-R VCCI CCC SASO MIC/RRL, Republic of Korea EMI Standard - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 58
www.dell.com | support.dell.com 58 Appendices - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 59
Energy, 35 F Firmware Upgrading, 49 Firmware CRCs, 43 FLASH Upgrade, 9 Flash Upgrading, 49 K Keep Alive, 7 L Legacy KVM, 21 Legacy Switches Adding, 20 M Memory Tests, 43 P Password Changing, 35 Server names Assigning, 28 SIP, 51 Offline, 25 Resetting, 38 Upgrading, 51 Soft switching, 25 Index 59 - Dell PowerEdge 2161DS | Dell 180AS/2160AS Analog Console Switch User's Guide - Page 60
Status flag Controlling, 33 Positioning, 34 Switch status, 24 System Diagnostics Running, 42 T Tiering, 9, 18 V Version Information Displaying, 37 60 Index
www.dell.com | support.dell.com
Dell™ Console Switch
Console Switch
Installer/User’s Guide
Model: Console Switch