Dell PowerEdge 2161DS Dell 180AS/2160AS Analog Console Switch User's Guide - Page 41

Clear, Commands, Scan Time

Page 41 highlights

Figure 3-16. Scan Dialog Box 3 The dialog box contains a listing of all servers attached to your appliance. Click the check box next to the servers you wish to scan. -orDouble-click on a server's name or port. -orPress and the number of the server you wish to scan. You can select up to 16 servers from the entire list. 4 In the Scan Time box, type the number of seconds (from 3 to 99) of desired time before the scan moves to the next server in the sequence. 5 Click OK. To remove a server from the scan list: 1 In the Scan dialog box, deselect the check box next to the server to be removed. -orDouble-click on the server's name or port. -orClick the Clear button to remove all servers from the scan list. 2 Click OK. To set the Scan duration: 1 Type a value in the Scan Time box. The duration you type must be a minimum of 3 seconds and a maximum of 255 seconds. To start the scan mode: 1 If the OSCAR interface is not open, press . The Main dialog box will appear. 2 Click Commands. The Commands dialog box appears. Basic Operation 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

Basic Operation
41
Figure 3-16.
Scan Dialog Box
3
The dialog box contains a listing of all servers attached to your appliance. Click the check box
next to the servers you wish to scan.
-or-
Double-click on a server’s name or port.
-or-
Press <
Alt
>
and the number of the server you wish to scan. You can select up to 16 servers from
the entire list.
4
In the
Scan Time
box, type the number of seconds (from 3 to 99) of desired time before the
scan moves to the next server in the sequence.
5
Click
OK
.
To remove a server from the scan list:
1
In the
Scan
dialog box, deselect the check box next to the server to be removed.
-or-
Double-click on the server’s name or port.
-or-
Click the
Clear
button to remove all servers from the scan list.
2
Click
OK
.
To set the Scan duration:
1
Type a value in the
Scan Time
box. The duration you type must be a minimum of 3 seconds
and a maximum of 255 seconds.
To start the scan mode:
1
If the OSCAR interface is not open, press
<
Print Screen
>.
The
Main
dialog box will appear.
2
Click
Commands
. The
Commands
dialog box appears.