Dell PowerEdge 2321DS User Manual

Dell PowerEdge 2321DS Manual

Dell PowerEdge 2321DS manual content summary:

  • Dell PowerEdge 2321DS | User Manual - Page 1
    Mounting and Cable Routing Procedures for Dell™ Digital KVM's (1082DS, 2162DS, 4322DS) A Dell™ Technical White Paper Dell™ │ Datacenter Infrastructure Engineering By Daniel Whittaker and Jose L. Flores August 2010
  • Dell PowerEdge 2321DS | User Manual - Page 2
    Routing Procedures for Dell™ Digital KVM's (1082DS, 2162DS, 4322DS) THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND. © 2010 Dell Inc. All rights
  • Dell PowerEdge 2321DS | User Manual - Page 3
    Mounting and Cable Routing Procedures for Dell™ Digital KVM's (1082DS, 2162DS, 4322DS) Contents Introduction ...3 Section 1: 0U Mounting Locations...3 1.1 Supported Locations in the PowerEdge™ 4210 and 2410 3 1.2 Supported Locations in the PowerEdge™ 4820, 4220, and 2420 5 Section 2: 1U Mounting
  • Dell PowerEdge 2321DS | User Manual - Page 4
    Mounting and Cable Routing Procedures for Dell™ Digital KVM's (1082DS, 2162DS, 4322DS) Page 2
  • Dell PowerEdge 2321DS | User Manual - Page 5
    Follow the instructions contained in the Rack Installation Guide to install the KVM into the 0U bracket. All illustrations in the following sections were created using a KVM 4322DS, however all the information is applicable to the 1082DS and 2162DS. 1.1 Supported Locations in the PowerEdge™ 4210 and
  • Dell PowerEdge 2321DS | User Manual - Page 6
    Routing Procedures for Dell™ Digital KVM's (1082DS, 2162DS, 4322DS) Please note that installation of the KVM where the ports face the ground is an unsupported orientation, and can cause damage to the KVM. See Figures 1 and 2 for the supported locations to mount the Digital KVM in the aforementioned
  • Dell PowerEdge 2321DS | User Manual - Page 7
    do not support mounting the KVM to the horizontal members of the rack. The 0U mounting space on the PowerEdge 4820, 4220, and 2420 offers restricted access to the ports on the back of the KVM unless the side panels can be removed. Please note that installation of the KVM where the ports face the
  • Dell PowerEdge 2321DS | User Manual - Page 8
    Routing Procedures for Dell™ Digital KVM's (1082DS, 2162DS, 4322DS) Figure 3: KVM Mounted on Vertical Member PowerEdge 4220 Vertical Top PowerEdge 2420 Vertical Section 2: 1U Mounting Locations 1U mounting is supported in all Dell racks. The rail kit provided with the KVMs installs without tools
  • Dell PowerEdge 2321DS | User Manual - Page 9
    Routing Procedures for Dell™ Digital KVM's (1082DS, 2162DS, 4322DS) 3.1 Four Post Front of Rack Cabling Follow the instructions contained in the Rack Installation Guide to install the KVM into the front of the rack. Once installed, use these instructions to install the cables. All illustrations
  • Dell PowerEdge 2321DS | User Manual - Page 10
    Mounting and Cable Routing Procedures for Dell™ Digital KVM's (1082DS, 2162DS, 4322DS) Figure 5: Four Post Rack: Routing Power and Data Cables 3.2 Two Post Flush Mount Cabling Follow the instructions contained in the Rack Installation Guide to install the KVM flush mount into the two post rack. Once
  • Dell PowerEdge 2321DS | User Manual - Page 11
    for Dell™ Digital KVM's (1082DS, 2162DS, 4322DS) Figure 7: Two Post Rack: System and Cables Installed 3.2.2 Routing the Power Cables and Data Cables 1.) After you have installed cables, route the power cables to one side, using hook and loop straps or tie downs to hold the cables (user supplied
  • Dell PowerEdge 2321DS | User Manual - Page 12
    for Dell™ Digital KVM's (1082DS, 2162DS, 4322DS) Figure 9: Two Post Rack: Routing Power and Data Cables (Optional Tie) Section 4: KVM Resolution Information 4.1 Dell KVM Resolution by Model Table 2 below shows the resolutions supported by Dell KVM model. The local port is the video port on
  • Dell PowerEdge 2321DS | User Manual - Page 13
    Digital KVM's (1082DS, 2162DS, 4322DS) 4.2 Server Interface Pod Matrix Tables 3 & 4 below show information about Dell Server Interface Pods (SIPs). If the table shows the EDID resolution is hardcoded, the maximum resolution the SIP reports to the OS cannot be changed from 1024x768 for the Local Port
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13

Mounting and Cable Routing
Procedures for Dell™ Digital KVM’s
(1082DS, 2162DS, 4322DS)
A Dell™ Technical White Paper
Dell™
Datacenter Infrastructure Engineering
By Daniel Whittaker and Jose L. Flores
August
2010