MEMTEST lane, failure, detected on, See Using the System Setup - memory installation
View all Dell PowerEdge T310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
Table 1-3. System Messages (continued) Message Memory set to minimum frequency. Memory tests terminated by keystroke. MEMTEST lane failure detected on x No boot device available Causes Corrective Actions The memory frequency If not an intentional setting, may be intentionally set check any other system lower for power conservation. messages for possible causes. The current memory configuration may support only the minimum frequency. Ensure that your memory configuration supports the higher frequency. See "General Memory Module Installation Guidelines" on page 108. POST memory test was terminated by pressing the spacebar. Information only. Invalid memory Ensure that the memory configuration. A mismatched modules are installed in memory module is installed. a valid configuration. See "General Memory Module Installation Guidelines" on page 108. Faulty or missing optical drive subsystem, hard drive, or hard-drive subsystem, or no bootable USB key installed. Use a bootable USB key, CD, or hard drive. If the problem persists, see "Troubleshooting an Internal USB Key" on page 157, "Troubleshooting a USB Device" on page 148, "Troubleshooting an Optical Drive" on page 158, and "Troubleshooting a Hard Drive" on page 160. See "Using the System Setup Program and UEFI Boot Manager" on page 57 for information on setting the order of boot devices. About Your System 45