Dell PowerStore 3000T EMC PowerStore Hardware Information Guide - Page 23

Shock and vibration, Platform condition, Response measurement level, Packaged system condition

Page 23 highlights

Shock and vibration Products have been tested to withstand the shock and random vibration levels. The levels apply to all three axes and should be measured with an accelerometer on the equipment enclosures within the cabinet and shall not exceed: Platform condition Non operational shock Operational shock Non operational random vibration Operational random vibration Response measurement level 10 G's, 7 ms duration 3 G's, 11 ms duration 0.40 Grms, 5-500 Hz, 30 minutes 0.21 Grms, 5-500 Hz, 10 minutes Systems that are mounted on an approved package have completed transportation testing to withstand the following shock and vibrations in the vertical direction only and shall not exceed: Packaged system condition Transportation shock Transportation random vibration Response measurement level 10 G's, 12ms duration ● 1.15 Grms ● 1 hour Frequency range 1-200 Hz Technical specifications 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

Shock and vibration
Products have been tested to withstand the shock and random vibration levels. The levels apply to all three axes and should be
measured with an accelerometer on the equipment enclosures within the cabinet and shall not exceed:
Platform condition
Response measurement level
Non operational shock
10 G’s, 7 ms duration
Operational shock
3 G’s, 11 ms duration
Non operational random vibration
0.40 Grms, 5–500 Hz, 30 minutes
Operational random vibration
0.21 Grms, 5–500 Hz, 10 minutes
Systems that are mounted on an approved package have completed transportation testing to withstand the following shock and
vibrations in the vertical direction only and shall not exceed:
Packaged system condition
Response measurement level
Transportation shock
10 G’s, 12ms duration
Transportation random vibration
1.15 Grms
1 hour Frequency range 1–200 Hz
Technical specifications
23