Dell PowerStore 5000X EMC PowerStore CLI Guide - Page 92
cutover, pause, async, Format
View all Dell PowerStore 5000X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 92 highlights
-async Perform asynchronous operation. cutover Commit an import session that is in a Ready_For_Cutover state. When the import session is created with the automatic_cutover attribute set to false, you must use the Cutover operation to complete the import. Until the cutover is complete, PowerStore forwards IO to the source volume to keep it in sync with all host IOs. You can cancel the import during this state if you want to continue using the source volume. Format import_session {-id | -name } cutover [-async] Action qualifiers -id Unique identifier of an import session -name Unique name of the existing object (import_session). -async Perform asynchronous operation. pause Pauses an ongoing import session. When this occurs, the background data copy stops, but IO to the source still occurs. Pause is only supported when the import job is in a in Copy_In_Progress state. You can resume or cancel the paused import. Format import_session {-id | -name } pause [-async] Action qualifiers -id Unique identifier of the import session -name Unique name of the existing object (import_session). -async Perform asynchronous operation. 65