8 Pre-Installation Requirements NOTE Because of potentially inconsistent voltage capabilities, the use of this washer with power created by gas powered generators, solar powered generators, wind powered generators or any other generator other than the local utility company is not recommended. WARNING ELECTRIC SHOCK HAZARD Certain internal parts are intentionally not grounded and may present a risk of electrical shock if contacted during installation. Do not contact the following parts while the appliance is energized • Pump • Drive motor • Electrical control boards • Water valves WARNING ELECTRICAL SHOCK HAZARD Improper connection of the equipment grounding conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded. Grounding type wall receptacle Do not, under any circumstances, cut, remove, or bypass the grounding prong. Power cord with 3-prong grounded plug Grounding requirements 1. The washer MUST be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electrical shock by a path of least resistance for electrical current. 2. Since your washer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, the plug MUST be plugged into an appropriate, copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances or in the absence of local codes, with the National Electrical Codes, ANSI/ NFPA 70 (latest edition), or in Canada, the Canadian electrical code C22.1 part 1. If in doubt, call a licensed electrician. DO NOT cut off or alter the grounding prong on the power supply cord. In situations where a two-slot receptacle is present, it is the owner's responsibility to have a licensed electrician replace it with a properly grounded three prong grounding type receptacle. Water supply requirements Hot and cold water faucets MUST be installed within hose length of your washer's water inlet. The faucets MUST be 3/4 inch (1.9 cm) with threading for laundry hose connection. Water pressure MUST be between 20 and 120 psi. Pressure difference between hot and cold cannot be more than 10 psi. Your water department can advise you of your water pressure. Drain system requirements 1. Drain capable of eliminating 17 gals (64.3 L) per minute. 2. A standpipe diameter of 1-1/4 in. (3.18 cm) minimum. 3. The standpipe height above the floor : Minimum height: 24 in. (61 cm) Maximum height: 96 in. (244 cm).

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

8
Pre-Installation Requirements
Water supply
requirements
Grounding requirements
Drain system
requirements
Grounding type wall receptacle
Power cord with
3-prong grounded plug
Do not, under
any circumstances,
cut, remove,
or bypass the
grounding prong.
1. The washer MUST be grounded.
In the event of malfunction or
breakdown, grounding will reduce the
risk of electrical shock by a path of
least resistance for electrical current.
2. Since your washer is equipped with
a power supply cord having an
equipment-grounding conductor and
a grounding plug, the plug MUST be
plugged into an appropriate, copper
wired receptacle that is properly
installed and grounded in accordance
with all local codes and ordinances
or in the absence of local codes, with
the National Electrical Codes, ANSI/
NFPA 70 (latest edition), or in Canada,
the Canadian electrical code C22.1
part 1. If in doubt, call a licensed
electrician. DO NOT cut off or alter the
grounding prong on the power supply
cord. In situations where a two-slot
receptacle is present, it is the owner’s
responsibility to have a licensed
electrician replace it with a properly
grounded three prong grounding type
receptacle.
Hot and cold water faucets MUST be
installed within hose length of your
washer’s water inlet. The faucets MUST be
3/4 inch (1.9 cm) with threading for laundry
hose connection. Water pressure MUST
be between 20 and 120 psi. Pressure
difference between hot and cold cannot be
more than 10 psi. Your water department
can advise you of your water pressure.
1. Drain capable of eliminating 17 gals
(64.3 L) per minute.
2. A standpipe diameter of 1-1/4 in.
(3.18 cm) minimum.
3. The standpipe height above the floor :
Minimum height:
24 in. (61 cm)
Maximum height:
96 in. (244 cm).
NOTE
Because of potentially inconsistent
voltage capabilities, the use of this
washer with power created by gas
powered generators, solar powered
generators, wind powered generators or
any other generator other than the local
utility company is not recommended.
WARNING
ELECTRICAL SHOCK HAZARD
Improper connection of the equipment
grounding conductor can result in a
risk of electrical shock. Check with a
licensed electrician if you are in doubt
as to whether the appliance is properly
grounded.
WARNING
ELECTRIC SHOCK HAZARD
Certain internal parts are intentionally
not grounded and may present a risk
of electrical shock if contacted during
installation. Do not contact the following
parts while the appliance is energized
• Pump
• Drive motor
• Electrical control boards
• Water valves