FX-1180/FX-880 Service Manual, Adjustment, Rev.B, Do not rotate the PLATEN during
UPC - 010343846746
View all Epson FX 890 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 75 highlights
FX-1180/FX-880 Service Manual Chapter 5 Adjustment 10. Insert a screwdriver into the countersink located on the left side of the SHAFT,CR,GUIDE and turn it until the PLATEN and Printhead come in light contact. 11. Move the carriage assembly to the left end. 12. Insert the thickness gauge (0.38 mm) between the Printhead and the PLATEN. 13. Insert the screwdriver into the countersink and turn it until the PLATEN and Printhead come in light contact. 14. Repeat the steps from 10 to 13, rotating the BUSHING,PARALLELISM,ADJUST until the parallelism gaps at the right and left become less than 0.02 mm. 15. When the parallelism gaps at the right and left are less than 0.02 mm, move the carriage assembly to the center of the printable area. 16. Insert the thickness gauge between the printhead and the PLATEN, and turn the SHAFT,CR,GUIDE so that the platen gap becomes 0.365 ± 0.015 mm. 0 .3 6 5 + /-0 .0 1 5 P LA TE N P r in th e a d Figure 5-3. Platen Gap 17. When the adjustment is complete, tighten the hexagon nut and the washer securing the adjust lever. 18. Remove the printhead once, and install the ribbon mask. 19. Attach the printhead back onto the carriage assembly. 9CHECK POINT Do not rotate the PLATEN during the adjustment. Rev.B 5-3