Epson TM T88II Technical Reference - Page 25

TM-T88II/T88III Technical Reference Guide - tm t88iii usb interface

Page 25 highlights

TM-T88II/T88III Technical Reference Guide Note: With the TM-T88III, the DIP SW2-5 setting is enabled only when DIP SW1-2 is set to OFF and the receive buffer is set to 4KB. With the older TM-T88II model, be sure to set DIP SW2-5 to OFF before use. Otherwise, the printer may no longer function correctly. When the TM-T88II is used or when the TM-T88III is used with DIP SW1-2 set to ON, the BUSY state is canceled when "26 bytes remaining in receive buffer" are reached, regardless of DIP SW2-5 setting. Do not change the settings of DIP SW2-2 and SW2-6. Otherwise, the printer may no longer function correctly. 2.2.2.2 DIP switch settings for other interface specifications The following DIP switch functions are for parallel interface/USB/Ethernet model printers. Note: * Factory setting Table 2-6 Parallel/USB/Ethernet DIP switch bank 1 SW Function 1-1 Automatic line feed 1-2 Receive buffer size 1-3, 1-8 Not defined (Always use printer with these switches set to OFF.) ON Enabled at all times 45 bytes - OFF Disabled at all times * 4KB * - * Table 2-7 Parallel/USB/Ethernet DIP switch bank 2 SW Function 2-1 Handshake (BUSY conditions) 2-2 Reserved (do not change setting) 2-3, 2-4 Print density selection/low-power mode 2-5 Conditions for canceling receive buffer BUSY state 2-6, 2-7 Reserved (do not change setting) 2-8 Pin #31reset signal (do not change setting) ON OFF • Receive buffer full • Offline * • Receive buffer full Fixed to OFF (See separate table.) (See separate table.) Fixed to OFF Fixed to ON DIP SW2-1: For details on the BUSY condition, also refer to "Busy State" (page 3-11). Rev. A Setup 2-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Rev. A
Setup
2-5
TM-T88II/T88III Technical Reference Guide
Note:
With the TM-T88III, the DIP SW2-5 setting is enabled only when DIP SW1-2 is set to OFF and the
receive buffer is set to 4KB.
With the older TM-T88II model, be sure to set DIP SW2-5 to OFF before use. Otherwise, the printer may
no longer function correctly.
When the TM-T88II is used or when the TM-T88III is used with DIP SW1-2 set to ON, the BUSY state
is canceled when “26 bytes remaining in receive buffer” are reached, regardless of DIP SW2-5 setting.
Do not change the settings of DIP SW2-2 and SW2-6. Otherwise, the printer may no longer function
correctly.
2.2.2.2
DIP switch settings for other interface specifications
The following DIP switch functions are for parallel interface/USB/Ethernet model printers.
Note:
* Factory setting
DIP SW2-1: For details on the BUSY condition, also refer to
“Busy State” (page 3-11)
.
Table 2-6
Parallel/USB/Ethernet DIP switch bank 1
SW
Function
ON
OFF
1-1
Automatic line feed
Enabled at all times
Disabled at all times *
1-2
Receive buffer size
45 bytes
4KB *
1-3, 1-8
Not defined
(Always use printer with these switches set to OFF.)
— *
Table 2-7
Parallel/USB/Ethernet DIP switch bank 2
SW
Function
ON
OFF
2-1
Handshake (BUSY conditions)
Receive buffer full
Offline *
Receive buffer full
2-2
Reserved (do not change setting)
Fixed to OFF
2-3, 2-4
Print density selection/low-power mode
(See separate table.)
2-5
Conditions for canceling receive buffer BUSY state
(See separate table.)
2-6, 2-7
Reserved (do not change setting)
Fixed to OFF
2-8
Pin #31reset signal (do not change setting)
Fixed to ON