    1551A Ex/1552A Ex Stik Thermometer Users Manual November 2010 © 2010 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
  • Fluke 1552A-12 | User Manual - Page 2
    normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales
  • Fluke 1552A-12 | User Manual - Page 3
    Table of Contents Title Page Introduction...1 Features...1 How to Contact Fluke 2 Safety Information 2 ATEX Safety Information 3 Symbols ...4 Approvals ...4 Operation ...5 Immersion Depth and Usage 5 Display and Controls 7 Primary Display 8 Stability Display 8 Setup and Configuration 8
  • Fluke 1552A-12 | User Manual - Page 4
    1551A Ex/1552A Ex Users Manual ii
  • Fluke 1552A-12 | User Manual - Page 5
    List of Tables Table Title Page 1. Symbols...4 2. Approved Batteries 12 iii
  • Fluke 1552A-12 | User Manual - Page 6
    1551A Ex/1552A Ex Users Manual iv
  • Fluke 1552A-12 | User Manual - Page 7
    List of Figures Figure Title Page 1. Probe Measurements 5 2. Immersion Depth...6 3. Display and Controls 7 4. Battery Replacement 12 v
  • Fluke 1552A-12 | User Manual - Page 8
    1551A Ex/1552A Ex Users Manual vi
  • Fluke 1552A-12 | User Manual - Page 9
    Introduction The Stik Thermometer (the Product) is a precision digital thermometer that can be used as an alternative to mercury liquid-in-glass (LIG) thermometers. It can also be used as a reference standard for other types of digital or analog thermometers. Because of its intrinsically safe
  • Fluke 1552A-12 | User Manual - Page 10
    print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. Safety Information A Warning identifies Use only specified approved batteries in the Product. Refer to the battery replacement instructions for a list of approved batteries. • Do not use and disable
  • Fluke 1552A-12 | User Manual - Page 11
    Product damage can occur. Violation of applicable legislation can also occur. Read the full manual before you use the Product. To make sure of safe Product operation, fully follow all instructions and warnings in the manual. If you are not sure (due to translation and/or printing errors), refer to
  • Fluke 1552A-12 | User Manual - Page 12
    are explained in Table 1. Table 1. Symbols Symbol J Meaning Earth ground Symbol M Battery Meaning W ~ P Risk of Danger. Important information. See Manual. X Do not dispose of this product as unsorted municipal waste. Go to Fluke's website for recycling information. ( Conforms to relevant
  • Fluke 1552A-12 | User Manual - Page 13
    Stik Thermometer Operation Operation Immersion Depth and Usage WCaution To prevent possible damage to the Product or to equipment under test, do not immerse the Probe beyond the maximum immersion depth. This may damage its internal electronics. Allow enough time for the Probe to stabilize before
  • Fluke 1552A-12 | User Manual - Page 14
    1551A/1552A Ex Users Manual The minimum immersion depth for the Probe is 3.5 inches in a stirred fluid heat source. It is recommended that you make sure of the minimum immersion
  • Fluke 1552A-12 | User Manual - Page 15
    Stik Thermometer Operation Display and Controls The Display and Controls are explained below and in the Setup and Configuration section. See Figure 3. 6 7 5 10 9 1 2 3 4 8 Number A B C D E F G H I J Item D A B C Primary Display Icon area Stability Display Arrow Buttons M E gjo001.eps
  • Fluke 1552A-12 | User Manual - Page 16
    1551A/1552A Ex Users Manual Primary Display Push Ato toggle the numeric display between the current reading, minimum, maximum, and 1-minute trend values in °C or °F as calculated since power up
  • Fluke 1552A-12 | User Manual - Page 17
    Stik Thermometer Operation Auto-Off Selection The Auto-off parameters control when the Product automatically turns off after inactivity on the keypad. K Increase the auto-off setting and the primary data field from "OFF" to 1 minute and stopping at 20 minutes. L Decrease the auto-off setting
  • Fluke 1552A-12 | User Manual - Page 18
    1551A/1552A Ex Users Manual Display Resolution Display resolution is the number of digits to the right of the decimal point. The settings are 0.1, 0.01, or 0.001. K Change the resolution
  • Fluke 1552A-12 | User Manual - Page 19
    Stik Thermometer Maintenance Logging Interval Push C to enter the data edit mode. ENTER is ignored if presently logging data. K Change the logging interval setting to the subsequent item in the list, cycling from the last to the first. L Change the logging interval setting to the previous item in
  • Fluke 1552A-12 | User Manual - Page 20
    1551A/1552A Ex Users Manual To change the batteries, see Figure 4: 1. Use a flat-blade screwdriver to remove the battery door screw. 2. Remove the battery door to access the three AAA
  • Fluke 1552A-12 | User Manual - Page 21
    in the lower right of the display when battery level is low. Replace batteries per recommendations found in the specifications section of this manual. Calibration For calibration information, refer to the document on the documentation CD. SCPI Commands For a list of the SCPI commands, refer to the
  • Fluke 1552A-12 | User Manual - Page 22
    1551A/1552A Ex Users Manual Battery Life Approximately 300 hours without back light Battery Save (auto-off) Range Selectable from 1 to 30 minutes or can be disabled Size (readout only
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22

November 2010
© 2010 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
1551A Ex/1552A Ex
Stik Thermometer
Users Manual