Fluke 192C FE 192,196,199 C Users Manual - Page 115

Environmental, Safety, Max. Floating Voltage

Page 115 highlights

Environmental Environmental MIL-PRF-28800F, Class 2 Temperature Operating: battery only 0 to 50 °C (32 to 122 °F) power adapter 0 to 40 °C (32 to 104 °F) Storage 20 to +60 °C (-4 to +140 °F) Humidity Operating: 0 to 10 °C (32 to 50 °F noncondensing 10 to 30 °C (50 to 86 °F 95 % 30 to 40 °C (86 to 104 °F 75 % 40 to 50 °C (104 to 122 °F 45 % Storage: -20 to +60 °C (-4 to +140 °F noncondensing Altitude Operating 3 km (10 000 feet) Storage 12 km (40 000 feet) Vibration (Sinusoidal max. 3 g Shock max. 30 g Electromagnetic Compatibility (EMC) Emission and immunitiy EN-IEC61326-1 (1997) Enclosure Protection IP51, ref: IEC529 9 Specifications Environmental Safety Designed for 1000 V measurements Category II , 600 V measurements Category III , Pollution Degree 2, per: • ANSI/ISA S82.01-1994 • EN/IEC61010-1 : 2001 • CAN/CSA-C22.2 No.1010.1-92 • UL3111-1 Max. Input Voltages Input A and B directly 300 V CAT III Input A and B via 10:1 probe 1000 V CAT II 600 V CAT III METER/EXT TRIG inputs 1000 V CAT II 600 V CAT III Max. Floating Voltage From any terminal to earth ground .......... 1000 V CAT II 600 V CAT III Between any terminal 1000 V CAT II 600 V CAT III Voltage ratings are given as "working voltage". They should be read as Vac-rms (50-60 Hz) for AC sinewave applications and as Vdc for DC applications. 107

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122

Specifications
Environmental
9
107
Environmental
Environmental
.........................
MIL-PRF-28800F, Class 2
Temperature
Operating:
battery only
...........................
0 to 50
°
C (32 to 122
°
F)
power adapter
......................
0 to 40
°
C (32 to 104
°
F)
Storage
.............................
-20 to +60
°
C (-4 to +140
°
F)
Humidity
Operating:
0 to 10
°
C (32 to 50
°
F)
.......................
noncondensing
10 to 30
°
C (50 to 86
°
F)
....................................
95 %
30 to 40
°
C (86 to 104
°
F)
...................................
75 %
40 to 50
°
C (104 to 122
°
F)
.................................
45 %
Storage:
-20 to +60
°
C (-4 to +140
°
F)
...............
noncondensing
Altitude
Operating
..........................................
3 km (10 000 feet)
Storage
...........................................
12 km (40 000 feet)
Vibration (Sinusoidal)
..........................................
max. 3 g
Shock
................................................................
max. 30 g
Electromagnetic Compatibility (EMC)
Emission and immunitiy
............
EN-IEC61326-1 (1997)
Enclosure Protection
.............................
IP51, ref: IEC529
Safety
Designed for 1000 V measurements Category II , 600 V
measurements Category III , Pollution Degree 2, per:
ANSI/ISA S82.01-1994
EN/IEC61010-1 : 2001
CAN/CSA-C22.2 No.1010.1-92
UL3111-1
Max. Input Voltages
Input A and B directly
...............................
300 V CAT III
Input A and B via 10:1 probe
...................
1000 V CAT II
600 V CAT III
METER/EXT TRIG inputs
........................
1000 V CAT II
600 V CAT III
Max. Floating Voltage
From any terminal to earth ground
..........
1000 V CAT II
600 V CAT III
Between any terminal
..............................
1000 V CAT II
600 V CAT III
Voltage ratings are given as “working voltage”. They
should be read as Vac-rms (50-60 Hz) for AC sinewave