Fluke 355 Fluke 353 & 355 Users Manual

Fluke 355 Manual

Fluke 355 manual content summary:

  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 1
    ® 353/355 Clamp Meter Users Manual PN 2842223 October 2007 © 2007 Fluke Corporation, All rights reserved. Printed in China. All product names are trademarks of their respective companies.
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 2
    to extend any other warranty on Fluke's behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 3
    the Meter ...8 Measuring AC or DC Current 8 Measuring Inrush Current 9 Measuring AC and DC Voltage (355 only 10 Testing Continuity (355 only 12 Measuring Resistance (355 only 13 Maintenance...14 Cleaning the Meter ...14 Changing the Batteries 14 User Replaceable Parts 14 Specifications ...15
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 4
    353/355 Users Manual ii
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 5
    List of Tables Table Title Page 1. Explanation of Symbols ...4 2. Features and Buttons ...5 3. Rotary Switch Positions...6 4. Display...7 iii
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 6
    353/355 Users Manual iv
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 7
    List of Figures Figure Title Page 1. Feature Locations...5 2. The Display ...7 3. Connecting the Meter ...8 4. Measuring Inrush Current...9 5. AC Voltage Measurement ...10 6. DC Voltage Measurement ...11 7. Measuring Continuity...12 8. Measuring Resistance ...13 v
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 8
    353/355 Users Manual vi
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 9
    measures ac, dc, true rms voltage, and resistance. The Meter ships with: • TL224 Test leads (355 only) • AC285 Clips (355 only) • TP74 Test Probes (355 only) • Soft carrying case • 6 AA/LR6 Batteries, installed • 353/355 Users Manual (7 languages) Clamp Meter Contacting Fluke To contact Fluke, call
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 10
    353/355 Users Manual Safety Information XWWarnings: Read First To avoid possible electric shock or personal injury: • Use the Meter only as specified in this manual or the protection provided by the Meter might be impaired. • Avoid working alone so assistance can be rendered. • Never measure ac
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 11
    Meter. Clamp Meter Safety Information • To avoid false readings that can lead to electrical shock and injury, replace the battery as soon as the low battery indicator (B) appears. Check Meter operation on a known source before and after use. • When servicing, use only specified replacement parts
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 12
    353/355 Users Manual Symbol W X , T B J B F ~ P ; N10140 CAT III CAT IV ) Table 1. Explanation of Symbols Explanation Risk of danger. Important information. Refer to operation instructions such as an electricity meter or an overhead or underground utility service. Canadian Standards Association 4
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 13
    Figure 1 and Tables 2 and 3 for a list of features. 16 1 15 14 13 12 11 10 9 355 AC/DC CLAMP METER MAXMINAVGLIVE Manual Range Auto Range 2000 A k TRUE RMS 600 V CAT A OFF A AC+DC A V V VAC+DC RANGE HOLD ZERO INRUSH Hz MIN MAX FILTER COM V 600 V CAT 1000 V CAT 2 3 4 5 6 87 fbq03
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 14
    Position 353/355 Position Function Position Function OFF Meter is powered down ? AC current A DC current AC + DC A Combined ac + dc (true rms) current reading. Additional Positions (355 Only) Position Function Position Function K AC voltage L DC voltage Combined ac + dc V AC + DC
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 15
    16 15 14 MAXMINAVGLIVE Manual Range Auto Range 13 12 k 11 Figure 2. The Display 5 6 7 8 9 10 fbq01.eps Clamp Meter Features Table 4. Display designates the real- time reading. F Manual or Auto Range is active G Amps or Volts is active H AC and DC mode is active I Resistance mode
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 16
    353/355 Users Manual Using the Meter XW Warning To avoid electric shock or personal injury: • When measuring current, center the conductor in the clamp. • When making current measurements, disconnect the test leads from the Meter. • Keep fingers behind Tactile Barrier. See Meter Features. Measuring
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 17
    is shown on the Meter display. Off 1 Clamp Meter Using the Meter On 355 AC/DC CLAMP METER Auto Range TRUE RMS 2000 A 600 V CAT A OFF A AC+DC A V V VAC+DC RANGE HOLD ZERO INRUSH Hz MIN MAX FILTER COM V 600 V CAT 1000 V CAT 2A INRUSH 3 355 AC/DC CLAMP METER Auto Range TRUE RMS
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 18
    353/355 Users Manual Measuring AC and DC Voltage (355 only) To measure ac or dc voltage: 1. Turn the rotary ac voltage, press Gto view the frequency reading on the frequency display. See Figures 5 and 6. 10 353 AC/DC CLAMP METER Auto Range 2000 A TRUE RMS 600 V CAT A OFF A AC+DC A V V VAC+DC
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 19
    355 AC/DC CLAMP METER Auto Range 2000 A TRUE RMS 600 V CAT A OFF A AC+DC A V V VAC+DC RANGE HOLD ZERO INRUSH Hz MIN MAX FILTER COM V 600 V CAT 1000 V CAT Figure 6. DC Voltage Measurement fbq06.eps Clamp Meter Using the Meter 11
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 20
    Ω. See Figure 7. 355 AC/DC CLAMP METER Auto Range 2000 A TRUE RMS 600 V CAT A OFF A AC+DC A V V VAC+DC RANGE HOLD ZERO INRUSH Hz MIN MAX FILTER COM V 600 V CAT 1000 V CAT 355 AC/DC CLAMP METER Auto Range 2000 A TRUE RMS 600 V CAT A OFF A AC+DC A V V VAC+DC RANGE HOLD ZERO
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 21
    aware that dangerous voltages may be present at the input terminals and may not be displayed Clamp Meter Using the Meter 355 AC/DC CLAMP METER Auto Range 2000 A TRUE RMS 600 V CAT A OFF A AC+DC A V V VAC+DC RANGE HOLD ZERO INRUSH Hz MIN MAX FILTER COM V 600 V CAT 1000 V CAT Figure
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 22
    353/355 Users Manual Maintenance XW Warning To avoid electrical shock, or personal injury: • Repairs or servicing not covered in this manual should be performed only by qualified personnel. • Disconnect test leads from the Meter before removing its back cover. • Never use the Meter with the back
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 23
    Resolution Accuracy > 10 A 40 A 10 mA 3.5 % rdg + 15 digits 400 A 100 mA 3.5 % rdg + 5 digits 2000 A; 1400 ac rms 1 A 3.5 % rdg + 5 digits Clamp Meter Specifications Trigger Level for Inrush 0.50 A 5.0 A 5 A Trigger Level for Hz Filter OFF 2.50 A 2.5 A 8 A Trigger Level for Hz Filter
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 24
    353/355 Users Manual Voltage Measurement (355 only) 10 Hz to 100 Hz 600 and 1000 V ranges V 400 V 100 mV 1 % rdg + 5 digits 6 V 600 V AC RMS 1 V 1 % rdg + 5 digits 6 V 1000 V DC 1 V 1 % rdg + 5 digits N/A Voltage Measurement (355 only) 100.1 Hz to 1 kHz 600 and 1000 V ranges have 10 %
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 25
    Continuity Beeper (355) On at ≤ 30 Ω Off at ≥ 100 Ω Frequency Measurement Measurement 100.1 Hz to 1 kHz 0.5 % + 5 counts Trigger Level Refer to current and voltage tables Clamp Meter Specifications General Specifications Batteries: 6- 1.5 V AA NEDA 15 A or IEC LR6 Test Leads: Rated to 1000 V
  • Fluke 355 | Fluke 353 & 355 Users Manual - Page 26
    353/355 Users Manual Standards and Agency Approval Specifications Design Standards and Compliance EN61010-032 CAT IV 600 V, IEC/EN 61326-1:1997 Agency Approvals Over-voltage Category P, ), ;, ~ N10140 IEC61010-1 CAT III 1000 V, CAT IV 600 V Environmental Specifications , EMC FCC part 15, IEC/EN
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

®
353/355
Clamp Meter
Users Manual
PN 2842223
October 2007
© 2007 Fluke Corporation, All rights reserved. Printed in China.
All product names are trademarks of their respective companies.