Fluke 355 Fluke 353 & 355 Users Manual - Page 13

Features, Feature Locations 355 shown, Table 2. Features and Buttons - ac dc clamp meter

Page 13 highlights

Features See Figure 1 and Tables 2 and 3 for a list of features. 16 1 15 14 13 12 11 10 9 355 AC/DC CLAMP METER MAXMINAVGLIVE Manual Range Auto Range 2000 A k TRUE RMS 600 V CAT A OFF A AC+DC A V V VAC+DC RANGE HOLD ZERO INRUSH Hz MIN MAX FILTER COM V 600 V CAT 1000 V CAT 2 3 4 5 6 87 fbq03.eps Figure 1. Feature Locations (355 shown) Clamp Meter Features Table 2. Features and Buttons Number A B C D E F G H I J K Description Current sensing clamp Rotary function switch Hold button- freezes the display reading and releases the reading when pressed a second time Zero button- Clears last reading from the display and establishes a baseline for ac + dc and dc current readings. Hz button- press to see frequency in the secondary display. Low Pass Filter button- Press to turn on the low pass filter. The filter eliminates high frequency noise such as from a ASD or VFD motor speed controller. Volts/Ohm input terminal. (355 only) Common input terminal. (355 only) Min Max button -When first pressed, the Meter shows maximum input. With subsequent presses, the minimum and the average inputs are shown. Hold for 2 seconds to exit min max mode. This function works in current, voltage and Frequency modes when activated. Inrush button- Press this button to enter inrush mode. Press it a second time to exit. Range button- press to change range or to turn off auto range. 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

Clamp Meter
Features
5
Features
See Figure 1 and Tables 2 and 3 for a list of features.
A
A
OFF
A
AC+DC
V
A
A
OFF
A
V
AC+DC
V
AC+DC
COM
V
600 V CAT
1000 V CAT
HOLD
RANGE
ZERO
INRUSH
MIN MAX
Hz
FILTER
MAXMINAVGLIVE
Manual
Auto
Range
Range
k
355
AC/DC CLAMP METER
2000 A
600 V CAT
TRUE RMS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
fbq03.eps
Figure 1. Feature Locations (355 shown)
Table 2. Features and Buttons
Number
Description
A
Current sensing clamp
B
Rotary function switch
C
Hold button- freezes the display reading and
releases the reading when pressed a second
time
D
Zero button- Clears last reading from the display
and establishes a baseline for ac + dc
and dc
current readings.
E
Hz button- press to see frequency in the
secondary display.
F
Low Pass Filter button- Press to turn on the low
pass filter. The filter eliminates high frequency
noise such as from a ASD or VFD motor speed
controller.
G
Volts/Ohm input terminal. (355 only)
H
Common input terminal. (355 only)
I
Min Max button -When first pressed, the Meter
shows maximum input. With subsequent
presses, the minimum and the average inputs
are shown. Hold for 2 seconds to exit min max
mode. This function works in current, voltage
and Frequency modes when activated.
J
Inrush button- Press this button to enter inrush
mode. Press it a second time to exit.
K
Range button- press to change range or to turn
off auto range.