Frigidaire FHPC3660LS Complete Owner's Guide (English) - Page 5

Intended use / Parts supplied - hood

Page 5 highlights

Intended use / Parts supplied 5 IMPORTANT 4 Save installation instructions for electrical inspector's use. The range hood must be connected with copper 5 wire only. The range hood should be connected directly to the fused disconnect (or circuit breaker) box through metal electrical conduit. 6 Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 - latest edition", or CSA Standards C22.1-94, Canadian 7 Electrical Code Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances. A U.L.- or C.S.A.-listed conduit connector must be provided at each end of the power supply conduit (at 8 the range hood and at the junction box). Copies of the standards listed may be obtained from: 9 * National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Road 10 Cleveland, Ohio 44131-5575 Power requirement: 11 120V~, 60Hz, 15 or 20A branch circuit Intended use 12 13 • Your range hood is intended for exhaust operation only. This range hood is not recommended to be used over indoor grills. Do not use it to exhaust 14 hazardous or explosive materials or vapors. Parts supplied 15 No. Part Qty. 16 1 Range hood 1 17 2 Glass cover 1 18 19 3 Upper and lower chimney 1 + 1 20 Upper bracket 1 Lower bracket 1 Collar 1 Recirculation kit (optional accessories) 1 Elux code: FHPRKT60LS Bulb 20W, 120V~, GU10 (pre- 4 assembled) Bolt, rubber 4 washer, washer sets Long screw (15/64" x 2-3/4") 4 Washer (dia. 23/32" x 1/4" 4 x 5/64") Washer (dia. 5/32" x 15/32" x 3/64") 8 M15/64" x 3/16" nut 4 Span washer (dia. 7/16" x 4 11/32" x 1/64") Washer (dia. 1/2" x 1/4" x 4 3/64") Allen key 1 10' extension chimney kit (optional accessories) 1 Elux code: FHP10X60LS Template (stencilled) Assembly template (stencilled) 1 Short screw 9/64" x 15/32" 14 Short screw 1/8" x 15/32" 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

5
IMPORTANT
Save
installation
instructions
for
electrical
inspector’s use.
The range hood must be connected with copper
wire only.
The range hood should be connected directly
to the fused disconnect (or circuit breaker) box
through metal electrical conduit.
Wire sizes must conform to the requirements of
the National Electrical Code ANSI/NFPA 70 – latest
edition”, or CSA Standards C22.1-94, Canadian
Electrical Code Part 1 and C22.2 No.0-M91 – latest
edition** and all local codes and ordinances.
A U.L.- or C.S.A.-listed conduit connector must be
provided at each end of the power supply conduit (at
the range hood and at the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association Batterymarch
Park Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
Power requirement:
120V~, 60Hz, 15 or 20A branch circuit
Intended use
Your range hood is intended for exhaust operation
only. This range hood is not recommended to be
used over indoor grills. Do not use it to exhaust
hazardous or explosive materials or vapors.
Parts supplied
No.
Part
Qty.
1
Range hood
1
2
Glass cover
1
3
Upper and lower
chimney
1
+
1
4
Upper bracket
1
5
Lower bracket
1
6
Collar
1
7
Recirculation kit
(optional
accessories)
Elux code:
FHPRKT60LS
1
8
Bulb
20W, 120V~,
GU10 (pre-
assembled)
4
9
Bolt, rubber
washer, washer
4
sets
10
Long screw
(15/64" x 2-3/4")
4
11
Washer
(dia. 23/32" x 1/4"
x 5/64")
4
12
Washer (dia. 5/32"
x 15/32" x 3/64")
8
13
M15/64" x 3/16"
nut
4
14
Span washer
(dia. 7/16" x
11/32" x 1/64")
4
15
Washer
(dia. 1/2" x 1/4"
x
3/64")
4
16
Allen key
1
17
10’ extension
chimney kit
(optional
accessories)
Elux code:
FHP10X60LS
1
18
Template
(stencilled)
Assembly template
(stencilled)
1
19
Short screw
9/64" x 15/32"
14
20
Short screw
1/8" x 15/32"
2
Intended use / Parts supplied