Table 1-2. Unit with Stand-alone Rack Characteristic Width Height Depth (Rack w/ Connectors) Unit Weight (GDL 59) Unit (GDL 59) and Stand-alone Rack Weight Specification 1.47 inches (3.73 cm) 6.91 inches (17.55 cm) 9.13 inches (23.19 cm) 1.5 lb (0.68 kg) 2.7 lb (1.22 kg) 1.4.2 Power Requirements Table 1-3. Input Voltage Characteristic Input Voltage Specification 14/28 Vdc See the Environmental Qualification Form for details on surge ratings and minimum/maximum operating voltages. Table 1-4. Maximum Current Specifications Unit Status Max Current @ 28 Vdc Off* 0.100 A On 0.572 A *DATA LINK REMOTE PWR OFF in active state Max Current @ 14 Vdc 0.100 A 1.15 A NOTE The GDL 59 is not certified for use on the emergency power bus. NOTE During the first five seconds of unit power-up, current is slightly higher due to backup capacitors being charged. Estimate initial power-up current to be ~150 mA @ 28 Vdc higher or ~300 mA @ 14 Vdc higher than the above figures. 1.4.3 General Specifications Table 1-5. General Specifications Characteristics Operating Temperature Range Humidity Altitude Range Software Compliance Maximum Average Power Input from Antenna Maximum Peak Power (1% Duty Cycle) Input from Antenna Specifications -55 to +70 °C. For more details see Environmental Qualification Form 95% non-condensing -1,500 ft to 55,000 ft RTCA/DO-178B Level D and E +15 dBm +30 dBm Page 1-4 Revision C GDL 59 Installation Manual 190-00837-00

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33

Page 1-4
GDL 59 Installation Manual
Revision C
190-00837-00
Table 1-2.
Unit with Stand-alone Rack
Characteristic
Specification
Width
1.47 inches (3.73 cm)
Height
6.91 inches (17.55 cm)
Depth (Rack w/ Connectors)
9.13 inches (23.19 cm)
Unit Weight (GDL 59)
1.5 lb (0.68 kg)
Unit (GDL 59) and Stand-alone Rack Weight
2.7 lb (1.22 kg)
1.4.2
Power Requirements
Table 1-3.
Input Voltage
Characteristic
Specification
Input Voltage
14/28 Vdc
See the Environmental Qualification Form for details
on surge ratings and minimum/maximum operating voltages.
Table 1-4.
Maximum Current Specifications
Unit Status
Max Current @ 28 Vdc
Max Current @ 14 Vdc
Off*
0.100 A
0.100 A
On
0.572 A
1.15 A
*DATA LINK REMOTE PWR OFF in active state
NOTE
The GDL 59 is not certified for use on the emergency power bus.
NOTE
During the first five seconds of unit power-up, current is slightly higher due to backup
capacitors being charged.
Estimate initial power-up current to be ~150 mA @ 28 Vdc
higher or ~300 mA @ 14 Vdc higher than the above figures.
1.4.3
General Specifications
Table 1-5.
General Specifications
Characteristics
Specifications
Operating Temperature Range
-55 to +70
°
C. For more details see
Environmental Qualification Form
Humidity
95% non-condensing
Altitude Range
-1,500 ft to 55,000 ft
Software Compliance
RTCA/DO-178B Level D and E
Maximum Average Power Input from Antenna
+15 dBm
Maximum Peak Power (1% Duty Cycle) Input from
Antenna