Garmin GRA 55 Maintenance Manual - Page 26
System Maintenance Manual GRA 55/5500 Bell 206 STC, Rev. 1,
View all Garmin GRA 55 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
Item Visual Inspection of the antennas Description/Procedure Visual inspection on the antenna: 1. Clean the antenna with water and mild soap. 2. Verify there are no cracks on the antenna and around attachment fasteners. 3. Verify that all sealing fillets around the antenna are in good condition. If the antenna is broken, cracked, or dented it must be replaced. Interval To be performed in In the event attachment is not secure, re-attach antenna alignment with Bell and complete the Electrical Bonding Test. 206B, 206L series maintenance In the event the antenna seal shows signs of damage, schedule. Every 100 complete the Electrical Bonding Test and re-seal the flight hours or every antenna. 12 months, whichever comes Visual inspection of the rotorcraft exterior skin around first. installed antenna: 1. Clean the exterior of the aircraft skin within a 10 Perform visual inch radius of the antenna with water and mild inspection in event of soap. suspected lightning 2. Inspect aircraft skin around the antenna footprint to strike. verify there are no cracks and aircraft skin is not deformed. 3. Verify that antenna fasteners are not loose. If the aircraft skin is cracked, or deformed, the internal structure must also be inspected for degradation in the local area. Refer to approved method defined in the Structural Repair Manual For Bell Model 206 Series Helicopters, BHT-206-SRM- 1, Section 3 for applicable repairs. 190-01277-A3 Rev. 1 System Maintenance Manual GRA 55/5500 Bell 206 STC Page 4-6