GE 60-774 Installation Instructions - Page 2
Installation Guidelines, Tools and Supplies Needed, Installation - security
UPC - 046188091768
View all GE 60-774 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Installation Guidelines Installation Guidelines R For the maximum number of bus devices and touchpads per panel see Table 2. Table 2. Maximum Bus Devices Per Panel Panel Maximum Bus Devices Advent 62 UltraGard 8 Concord 16 R Do not exceed the total panel output power when using panel power for bus devices and hardwired sensors that require it (see specific panel Installation Instructions). R Maximum current draw of each SuperBus 2000 8Z Input Module is 35 mA. R Do not exceed the maximum wire length from the panel to the module (see Table 3). Table 3: Maximum Wire Lengths Panel Maximum Wire Length Advent 22 ga. 1,800 ft./18 ga. 4000 ft. UltraGard 22 ga. 500 ft./18 ga. 1000 ft. Concord 22 ga. 1,800 ft./ 18 ga. 4,500 ft. R When using self or remotely powered devices with an Advent panel, do not exceed the maximum recommended wire length of 4000 feet using 22-gauge or larger wire. R Terminate each hardwired zone with a 2.0K ohm EOL resistor. For normally open circuits, wire the resistor in parallel. For normally closed circuits, wire the resistor in series. R Always install the EOL resistor at the last sensor or device on the circuit, not at the zone input terminals. Tools and Supplies Needed R Screwdrivers R Drill with bits R 3/8 -inch #6-32 self-tapping screws (included) R 2.0K ohm EOL resistors (49-467) (included) R 22-gauge or larger wire (18-gauge or larger for com- mercial applications) R 1/4-inch press-fit reed switch and magnet (not included) for cover tamper R 1/4-inch #6-32 self tapping screws (not included) for Advent cabinet mounting R Support standoff (included with Concord cabinet) Installation The module can be mounted R On a wall. R Inside an Advent cabinet. R Inside a Concord cabinet. R Inside a SuperBus module cabinet (60-698). Refer to the cabinet Installation Instructions for installation procedures. Ìi For UltraGard installations, the module must be mounted to a wall. The module will not fit in the UltraGard cabinet. Mounting the Module ÁIG"42 To prevent damaging the panel or module, remove the panel AC power and disconnect the backup battery(s) before installation. ÁIG"42 You must be free of all static electricity when handling electronic components. Touch a bare metal surface before touching the circuit board. To Mount the Module on a Wall 1. Remove the module cover and set it aside (Figure 2). PRESS DOWN HERE AND PULL AWAY FROM BASE 8557G47B.DS4 Figure 2. Removing the Cover 2. Place the back-plate on the wall and mark the three mounting holes (Figure 3). 3. Drill holes and insert appropriate anchors. 4. Secure the back-plate to the wall with included screws. 2