GE 60-774 Installation Instructions - Page 5
Installing a Cover Tamper Switch, Setting the Module Unit Numbers - alarm panel
UPC - 046188091768
View all GE 60-774 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Installing a Cover Tamper Switch Installing a Cover Tamper Switch Setting the Module Unit Numbers If you are mounting the module in its own plastic and not mounting it inside a cabinet, you need to add cover tamper detection. To do this, install a UL listed 1/4-inch press-fit reed switch on the module back-plate and wire the switch to one of the module zone input terminals or unused panel zone input terminals. Once programmed, if someone opens the module cover, the tamper switch opens and causes an alarm. The reed switch holder and magnet clip are located at the bottom of the back-plate (see Figure 3 for details). To install the tamper reed switch (Figure 9): 1. Slide the reed switch into the reed switch holder located on the module back-plate shown in Figure 9. 2. Insert the magnet into the nibs on the module cover. Remove the magnet clip from the module back-plate and press the magnet clip down over the magnet until it clicks into place (Figure 9). 3. Connect the normally closed reed switch (in series with a 2.0K ohm EOL resistor) to the module ZONE 1 (1) and ZONE COMMON (2) terminals as shown in Figure 8. The resistor should be located at the reed switch inside the module housing. MODULE BACK-PLATE MODULE COVER MAGNET TO ANY ZONE INPUT MAGNET CLIP REED SWITCH 2.0K OHM EOL RESISTOR (49-467) 9712G12A.DSF Figure 9. Installing the Reed Switch On Concord (software versions 1.0-1.6) and UltraGard Panels Locate the DIP switches on the module circuit board (Figure 1) and set switch 1 to "M" (on - for manual) (Figure 10). Set the remaining switches for the desired unit number. ÁIG"42 Do not change DIP switch settings once the panel is powered up. - UNIT NUMBER 0-7 for UltraGard - UNIT NUMBER 0-15 for Concord UNIT NUMBER 0 UNIT NUMBER 1 UNIT NUMBER 2 M ON M ON M ON A A A 1 234567 8 1 234567 8 1 234567 8 UNIT NUMBER 3 UNIT NUMBER 4 UNIT NUMBER 5 M ON M ON M ON A A A 1 234567 8 1 234567 8 1 234567 8 UNIT NUMBER 6 UNIT NUMBER 7 UNIT NUMBER 8 M ON M ON M ON A A A 1 234567 8 1 234567 8 1 234567 8 UNIT NUMBER 9 UNIT NUMBER 10 UNIT NUMBER 11 M ON M ON M ON A A A 1 234567 8 1 234567 8 1 234567 8 UNIT NUMBER 12 UNIT NUMBER 13 UNIT NUMBER 14 M ON M ON M ON A A A 1 234567 8 1 234567 8 1 234567 8 UNIT NUMBER 15--Do not use in Concord RF systems. M ON A 1 234567 8 9712G09A.DSF Figure 10. Module Unit Number DIP Switch Settings (Non-SuperBus 2000 panels) On Concord (software versions 2.0 or later) and Advent Panels Locate the DIP switches on the module circuit board (Figure 1) and set all switches to "A" (off - for automatic). The unit number will be automatically set when powering up the system. 5