GE PB970 Installation Instructions - Page 5

Power Cord And, Strain Relief Installation, Purchase

Page 5 highlights

Installation Instructions 3 POWER CORD AND STRAIN RELIEF INSTALLATION A Remove the terminal block cover (on the back of the range) by removing the screw, using a 1/4" nut driver. Do not discard the screw. C For power cord installations only (see the next step if using conduit), assemble the strain relief in the hole. Insert the power cord through the strain relief and tighten. Allow enough slack to easily attach the cord terminals to the terminal block. If tabs are present at the end of the winged strain relief, they can be removed for better fit. NOTE: Do not install the power cord without a strain relief. The strain relief bracket should be installed before reinstalling the rear range wiring cover. Terminal block Back of range Screw to remove terminal block cover Terminal block cover B Remove the knockout ring (13⁄8″) located on bracket directly below the terminal block. To remove the knockout, use a pair of pliers to bend the knockout ring away from the bracket and twist until ring is removed. NOTE: You only need to remove the knockout ring for power cord installation. Terminal block (appearance may vary) Strain relief Power cord Skip to Step 4 or 5. Bracket D For conduit installations only, purchase a squeeze connector matching the diameter of your conduit and assemble it in the hole. Insert the conduit through the squeeze connector and tighten. Allow enough slack to easily attach the wires to the terminal block. NOTE: Do not install the conduit without a squeeze connector. The squeeze connector should be installed before reinstalling the rear range wiring cover. Terminal block Knockout ring in bracket Knockout ring removed 5 Squeeze connector Conduit Skip to Step 6 or 7. Bracket

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

5
Installation Instructions
POWER CORD AND
STRAIN RELIEF INSTALLATION
Remove the terminal block cover (on the
back of the range) by removing the
screw, using a 1/4” nut driver.
Do not discard the screw.
Remove the knockout ring (1
3
±
8
) located
on bracket directly below the terminal
block. To remove the knockout, use a
pair of pliers to bend the knockout ring
away from the bracket and twist until
ring is removed.
NOTE:
You only need to remove the
knockout ring for power cord installation.
B
A
3
For power cord installations only
(see
the next step if using conduit), assemble
the strain relief in the hole. Insert the
power cord through the strain relief and
tighten. Allow enough slack to easily
attach the cord terminals to the terminal
block. If tabs are present at the end of
the winged strain relief, they can be
removed for better fit.
NOTE: Do not install the power cord
without a strain relief. The strain relief
bracket should be installed before
reinstalling the rear range wiring cover.
Skip to Step 4 or 5.
C
Terminal
block cover
Screw to
remove
terminal
block cover
Knockout ring
in bracket
Knockout
ring removed
Power cord
Strain relief
Terminal
block
Bracket
Back of range
Terminal block
(appearance
may vary)
For conduit installations only
, purchase a
squeeze connector matching the diameter
of your conduit and assemble it in the hole.
Insert the conduit through the squeeze
connector and tighten. Allow enough slack to
easily attach the wires to the terminal block.
NOTE:
Do not install the conduit without a
squeeze connector. The squeeze connector
should be installed before reinstalling the
rear range wiring cover.
Skip to Step 6 or 7.
D
Squeeze
connector
Terminal
block
Conduit
Bracket