GE PVM9005EJES Installation Instructions - Page 14
Warning
View all GE PVM9005EJES manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
Installation Instructions A3 ADJUST BLOWER MOTOR 1 Remove the screws holding the blower unit and the screws securing the blower plate. Remove the blower plate from the outer case by sliding it toward the back of the microwave and pulling up. Blower Motor Screws Blower Plate A3 $'-867%/2:(502725FRQW Fan Blades Wires Back of Mircrowave 3 Roll the blower so that fan blade openings are facing the top of the oven. Place the blower back into the opening. Rotate 90° Blower Motor Screw 2 Carefully pull out the blower unit. The wires will extend far enough to allow you to adjust the blower unit. Back of Mircrowave Note: Make sure the wires remain routed through the openings in the motor frame. To avoid damage to the fan motor wiring, insert motor carefully such that the fan motor wiring does not contact the microwave power cord bracket. WARNING: 5LVNRI(OHFWULF6KRFN Can cause injury or death. Do not pull or stretch the EORZHUXQLWZLULQJ0DNHVXUHWKHZLUHVDUHQRW pinched. 4 Slide the blower plate back onto the microwave by placing the side tabs into the slots and pushing gently until the back tab is seated into the rear slot. Replace 3 screws. Side Tab Side Slot Rear Tab Rear Slot 14