DRAM Timing Selectable (SPD) Quick and Expert allows the Channel Interleaving, Rank Interleaving, Channel A Timing Settings, and Channel B Timing Settings items to be configurable. Options are: Auto (default), Quick, Expert. Profile DDR Voltage Displays the memory voltage as 1.5V. Profile VTT Voltage The value displayed here is dependent on the CPU being used. Channel Interleaving Enables or disables memory channel interleaving. Enabled allows the system to simultaneously access different channels of the memory to increase memory performance and stability. Auto lets the BIOS automatically configure this setting. (Default: Auto) Rank Interleaving Enables or disables memory rank interleaving. Enabled allows the system to simultaneously access different ranks of the memory to increase memory performance and stability. Auto lets the BIOS automatically configure this setting. (Default: Auto) >>>>> Channel A/B Timing Settings CMOS Setup Utility-Copyright (C) 1984-2011 Award Software Channel A Timing Settings >>>>> Channel A Standard Timing Control x CAS Latency Time 9 x tRCD 9 x tRP 9 x tRAS 24 >>>>> Channel A Advanced Timing Control x tRC 33 x tRRD 4 x tWTR 5 x tWR 10 x tWTP 21 x tWL 7 x tRFC 74 x tRTP 5 x tFAW 20 x Command Rate (CMD) 1 >>>>> Channel A Misc Timing Control x IO Latency 1 x Round Trip Latency 34 Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Item Help Menu Level  Move Enter: Select F5: Previous Values +/-/PU/PD: Value F10: Save F6: Fail-Safe Defaults ESC: Exit F1: General Help F7: Optimized Defaults >>>>> Channel A/B Standard Timing Control CAS Latency Time Options are: Auto (default), 5~15. tRCD Options are: Auto (default), 1~15. tRP Options are: Auto (default), 1~15. tRAS Options are: Auto (default), 1~40. >>>>> Channel A/B Advanced Timing Control tRC Options are: Auto (default), 1~63. - 26 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

- 26 -
DRAM Timing Selectable (SPD)
Quick
and
Expert
allows the
Channel Interleaving
,
Rank Interleaving
,
Channel A Timing Settings
,
and
Channel B Timing Settings
items to be configurable. Options are: Auto (default), Quick, Expert.
Profile DDR Voltage
Displays the memory voltage as
1.5V
.
Profile VTT Voltage
The value displayed here is dependent on the CPU being used.
Channel Interleaving
Enables or disables memory channel interleaving.
Enabled
allows the system to simultaneously access
different channels of the memory to increase memory performance and stability.
Auto
lets the BIOS au-
tomatically configure this setting. (Default: Auto)
Rank Interleaving
Enables or disables memory rank interleaving.
Enabled
allows the system to simultaneously access dif-
ferent ranks of the memory to increase memory performance and stability.
Auto
lets the BIOS automati-
cally configure this setting. (Default: Auto)
>>>>>
Channel A/B Timing Settings
CMOS Setup Utility-Copyright (C) 1984-2011 Award Software
Channel A Timing Settings

: Move
Enter: Select
+/-/PU/PD: Value
F10: Save
ESC: Exit
F1: General Help
F5: Previous Values
F6: Fail-Safe Defaults
F7: Optimized Defaults
Item Help
Menu Level

>>>>>
Channel A Standard Timing Control
x
CAS Latency Time
9
Auto
x
tRCD
9
Auto
x
tRP
9
Auto
x
tRAS
24
Auto
>>>>>
Channel A Advanced Timing Control
x
tRC
33
Auto
x
tRRD
4
Auto
x
tWTR
5
Auto
x
tWR
10
Auto
x
tWTP
21
Auto
x
tWL
7
Auto
x
tRFC
74
Auto
x
tRTP
5
Auto
x
tFAW
20
Auto
x
Command Rate (CMD)
1
Auto
>>>>>
Channel A Misc Timing Control
x
IO Latency
1
Auto
x
Round Trip Latency
34
Auto
>>>>>
Channel A/B Standard Timing Control
CAS Latency Time
Options are: Auto (default), 5~15.
tRCD
Options are: Auto (default), 1~15.
tRP
Options are: Auto (default), 1~15.
tRAS
Options are: Auto (default), 1~40.
>>>>>
Channel A/B Advanced Timing Control
tRC
Options are: Auto (default), 1~63.