Haier AB12CS1ERA Service Manual - Page 8

U30HS1ERA

Page 8 highlights

>_]]VbTZR\ _^UZdZ_^Vb Item Model 4U30HS1ERA Function Rating capacity Power input (indoor + outdoor) Current input (indoor + outdoor) EER / COP Minimum capacity Minimum power input Maximum capacity Maximum power input (indoor + outdoor) Power source Max.Running current (indoor + outdoor) Power facor(under rating power input) Fuse size (recommended size) Indoor units number W W A W/W W W W W A / A A Cooling Heating 8100 9800 2220 2430 9.7 10.6 3.65 4.03 1500 1800 550 550 9800 10500 3800 3800 1PH, 220-230V~, 50/60Hz 16.5 16.5 99% 99% 25 2~4 Model / Manufacture TNB220FLHMC-L / MGC Compressor Fan system Oil charge and type Type Winding resistance(at 20℃) Fan type × Number Motor speed Fan motor model Motor type Ω r/min 870CC / FV50S Twin Rotary (DC inverter) 0.88 Axial × 1 Max. 860 EHDS80A100AS DC Outdoor unit Motor output/input power W 100/125 Air-flows (H/M/L) m³/h about 4000 Heat exchanger Type / Diameter Number of rows Face area mm TP2M / 7.0 3 m² about 0.75 Dimension External mm 948/340/840 (WxDxH) Package mm 1040/430/1000 Refrigerant control method PMVs Defrosting method Automatic by reversible cycle Crankcase heater power W 35 Noise level H/M/L dB(A) 58 Weight Net / Shipping kg / kg 76/87 Type / Charge kg R410A / 3.0 Refrigerant Total liquid piping length without recharge m less than 40 Recharge g/m 20 Piping Pipe size Liquid Gas mm 4* Φ6.35 mm 3* Φ9.52(A,B,C)+1*Φ12.7(D) Connecting method Flared Max.Drop between IU & OU m 15 Between Max.Drop between indoor units m 7.5 IU & OU Max.Piping length between IU & OU m 25 Max.Total length m 70 1. The above performance data are from the combination of 4U30HS1ERA+4*AS09CS1ERA. 2. Large drop and long piping installation will obviously reduce the total capacity. Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20 ℃DB Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7 ℃DB/6℃WB The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a sound pressure noise level. -8-

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

±²³³´µ¶·¸¹ º·µ ±²»¼·½·²»´µ
-8-
Cooling
Heating
W
8100
9800
W
2220
2430
A
9.7
10.6
W/W
3.65
4.03
W
1500
1800
W
550
550
W
9800
10500
W
3800
3800
A / A
16.5
16.5
99%
99%
A
Winding resistance(at 20
)
Motor speed
r/min
Motor output/input power
W
Air-flows (H/M/L)
m³/h
Type / Diameter
mm
Face area
External
mm
Package
mm
W
Noise level
H/M/L
dB(A)
Weight
Net / Shipping
kg / kg
Type / Charge
kg
m
Recharge
g/m
Liquid
mm
Gas
mm
Max.Drop between IU & OU
m
Max.Drop between indoor units
m
Max.Piping length between IU & OU
m
Max.Total length
m
Item
Model
4U30HS1ERA
Rating capacity
Function
Power input (indoor + outdoor)
Current input (indoor + outdoor)
EER / COP
Minimum capacity
Minimum power input
Maximum capacity
Maximum power input (indoor + outdoor)
Power source
1PH, 220-230V~, 50/60Hz
Max.Running current (indoor + outdoor)
Fuse size (recommended size)
25
Power facor(under rating power input)
0.88
Fan system
Axial × 1
Max. 860
Motor type
DC
100/125
PMVs
about 4000
Heat
exchanger
TP2M / 7.0
about 0.75
Number of rows
3
Refrigerant control method
Dimension
(WxDxH)
948/340/840
1040/430/1000
Indoor units number
2~4
Fan type × Number
Fan motor model
EHDS80A100AS
Outdoor unit
Compressor
TNB220FLHMC-L / MGC
870CC / FV50S
Twin Rotary (DC inverter)
70
Automatic by reversible cycle
Crankcase heater power
35
Pipe size
4*
Φ
6.35
Defrosting method
Connecting method
20
3*
Φ
9.52(A,B,C)+1*
Φ
12.7(D)
1. The above performance data are from the combination of 4U30HS1ERA+4*AS09CS1ERA.
2. Large drop and long piping installation will obviously reduce the total capacity.
Flared
Between
IU & OU
15
7.5
25
Norminal condition: indoor temperature (cooling): 27
DB/19
WB, indoor temperature (heating): 20
DB
Outdoor temperature(cooling): 35
DB/24
WB, outdoor temperature(heating): 7
DB/6
WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound
intensity meter. It is a sound pressure noise level.
Model / Manufacture
Oil charge and type
Type
Piping
Refrigerant
58
76/87
R410A / 3.0
Total liquid piping length without recharge
less than 40