  • Haier HC60D1VAR | User Manual - Page 1
    Installation & Operation Manual Central Air Conditioner 10 to 13 SEER 1.5 to 5 Tons Models: HC18-60A1VAR/S HC18-60C1VAR HC18-60D1VAR No.0010572324 K The information contained in this booklet is subject to change without notice.
  • Haier HC60D1VAR | User Manual - Page 2
    the introduction and disposal of refrigerants in this unit. Failure to air conditioner and may also endanger life and property. The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized components, accessories or devices. Attach the service
  • Haier HC60D1VAR | User Manual - Page 3
    6 6.3.Refrigerant piping 6 6.4.Electrical wiring 10 7.System Startup 11 8.Operation 12 9.Miscellaneous 12 9.1.Replacement parts 12 9.2.Troubleshooting guide 12 9.3.Wiring diagram 12 1.INTRODUCTION This manual contains the installation and operating instructions for your new air conditioner
  • Haier HC60D1VAR | User Manual - Page 4
    and electrical specifications are provided in Table 1 for 10 SEER systems respectively. Table 1: Model:HC18-60A1VAR/S 2 MODEL: HC18A1VAR HC24A1VAR HC30A1VAR HC36A1VAS HC42A1VAR HC48A1VAR HC60A1VAR Unit Supply Voltage 208/230-1-60 Normal Voltage Range Compressor Brand Minimum Circuit Amps
  • Haier HC60D1VAR | User Manual - Page 5
    W H Table 2:System Cooling Capacity Figure 1 Outdoor Unit With This Indoor Air handler Model Number Air Handler Compressor Cooling Capacity (Btu/h) SEER Rated HC18A1VAR HC24A1VAR HC30A1VAR HC36A1VAS HC42A1VAR HB2400VA1M20 HB2400VA1M20 HB3000VA1M20 HB3600VA1M20 HB4200VA1M25 brand Bristol
  • Haier HC60D1VAR | User Manual - Page 6
    4:System Cooling Capacity Outdoor Unit Model Number HC18C1VAR HC24C1VAR HC30C1VAR HC36C1VAR HC42C1VAR HC48C1VAR HC60C1VAR With This Indoor Air handler Air Handler Compressor Cooling Capacity (Btu/h) brand Sensible Total HB2400VC1M20 Bristol 14820 19000 HB2400VC1M20 Bristol 18720 24000
  • Haier HC60D1VAR | User Manual - Page 7
    to be installed in an area where contaminants are likely to be a problem, special attention should be given to the equipment location and exposure. attempting any installation: Structural strength of supporting members. Clearances and provision for servicing. Power supply and wiring. Location for
  • Haier HC60D1VAR | User Manual - Page 8
    cork pad. For rooftop application, make sure the building construction can support the weight and that proper consideration is given to the weather-tight air enters from three sides. Air discharges upward from the top of the unit. Refrigerant tube and electrical connections are made from the service
  • Haier HC60D1VAR | User Manual - Page 9
    or bends, to avoid capacity loss and increased operating costs. Refrigerant lines must be adequately supported. If metal strapping is used to secure the tubing, do on the piping and to prevent heat gain caused by surrounding air. Generally 3/8" wall thickness of Armflex or equivalent is satisfactory
  • Haier HC60D1VAR | User Manual - Page 10
    the liquid line to remove pressure. ! CAUTION - Condensing units are charged with refrigerant. Condensing unit liquid and suction valves are closed to contain the charge within the indoor liquid pipe orifice. Instructions on the field tubing connections and valve opening procedure are as follow: 8
  • Haier HC60D1VAR | User Manual - Page 11
    from entering the system. 2.Make sure that both refrigerant stop valves at the outdoor unit are closed. 3. 4.Remove the cap and Schrader valve core from the service port to protect the valve seals. 5.Wrap a removed prior to charging the system. Air in a system causes high condensing pressure
  • Haier HC60D1VAR | User Manual - Page 12
    service gage manifold to the valve service ports, being sure to evacuate lines. 3.Startup the system (Refer to the Section 7 - "System Startup"). Run system at least 10 minutes to allo System Superheat Ambient Return Air this appliance at the electrical service entrance. manual this instruction).
  • Haier HC60D1VAR | User Manual - Page 13
    run in cooling mode. 5.Check to see if compressor and outdoor fan are running correctly? 6.Check the refrigerant charge (see Instructions under "Charging the System"). 7.Replace service port caps. Service port cores are for system access only and will leak if not tightly capped. 8.Check unit for
  • Haier HC60D1VAR | User Manual - Page 14
    . 9.3. Wiring Diagram Refer to the appropriate wiring diagram included in this manual.(P14) Table 10:Troubleshooting Guide ! WARNING - Disconnect all electrical power to the unit before servicing. Disconnect power to both the indoor and outdoor units. NOTE: There may be more than one electrical
  • Haier HC60D1VAR | User Manual - Page 15
    load Insufficient Cooling Improper airflow Check - should be 400CFM/Ton Incorrect refrigerant charge Charge correctly per instruction. Air, non-condensibles or moisture in system Recover refrigerant, evacuate & recharge, add filter drier Incorrect voltage At compressor terminals, voltage
  • Haier HC60D1VAR | User Manual - Page 16
    HC18-60A1VAR/S HC18-60C1VAR HC18-60D1VAR Air Conditioner Wi ri ng Diagram 5 YL 6C S R RD BK RD OFM 6 M BR R S BR BK PU L1 BK L2 WH GND 208 power connect ions di rect ly to elect ric h eater kit pow er terminals. Consult heat er ki t inst allation instructions for complete det ails. 14
  • Haier HC60D1VAR | User Manual - Page 17
    Made in P.R.C.
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17

No.0010572324
K
10 to 13 SEER
1.5 to 5 Tons
Models: HC18-60A1VAR/S
HC18-60C1VAR
HC18-60D1VAR
Installation & Operation Manual
Central Air Conditioner
The information contained in this booklet is subject to change without notice.