Hayward OnCommand Model: ALL MODELS Installation - Page 15
VSC Pump Address Setting, Temperature Sensors, Base Station - base controller
View all Hayward OnCommand manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
VSC Pump Address Setting The VSC address must be set to 001 when using the VSC with the OnCommand. Refer to the TriStar Pump Owner's Manual (IS3220VSC) and Hayward document IS3220VSCAQLL for specific instructions on setting the pump address. Temperature Sensors The OnCommand utilizes 10K ohm thermistor type sensors. Three sensors (water temperature, air temperature and solar temperature) are included. If the OnCommand is being used to control a solar heating system, the solar sensor is required. The sensors are provided with a 15 ft. cable. If a longer cable is required, contact the Goldline Technical Support department for information on suitable cable types and splices. See page 2 and the diagram below for installation information. POOL/SPA SENSOR AIR SENSOR SOLAR SENSOR optional Base Station Plug in the pigtail connector from the wireless base station into the "wireless" connector on the main PCB in the OnCommand control unit. 12