Page 5 of 12 Pro-GridTM VERTICAL D.E. SERIES FILTER ISDE2423 REV C STARTING THE PUMP and FILTER SYSTEM WARNING Before Starting the Pump 1. Use ONLY Hayward clamp system components; DEX2421JKIT clamp system, DEX2421J2 nut/bolt assembly, DEX2422Z2 metal reinforced seal. Non-Hayward clamp components may fail in use and cause explosive component separation. Verify that upper and lower filter bodies are properly secured with the filter body clamp. Never rely on hand tightening the clamp nut to the clamp bolt. Using a ¾" socket on a torque wrench, torque clamp nut to clamp bolt to 150 inch-lbs. Verify that the filter manual air relief body is in the LOCK position, and no filter components are missing, damaged or not genuine Hayward components. (See Fig 2) 2. Close filter drain. Note: Filter plug requires an o-ring seal. (See Fig 4) 3. Open all system valves to allow water from the pool to the filtration system and from the filter to return to the pool. 4. Place the manual air relief valve in OPEN position. (See Fig 2) Starting Pump 1. When starting system pump, do not stand over or near filter. If water leakage appears at filter tank clamp, immediately turn off all system circulation pumps and all electrical power. Do not return to the filter until all water leakage has stopped. Reassemble the clamp system per the instructions on page 7 in this owner's manual to stop leak. 2. Return to filter to CLOSE manual air relief valve only when a steady stream of water (not air or, air and water mix) is discharged from the manual air relief valve. 3. To avoid damages to the grid elements, DO NOT operate the filter for more than a minute or two without the D.E. pre-coat. CLAMP NUT Tighten clamp bolt and nut using a torque wrench to 150 inch-lbs. Manual Air Relief Shown Open In Locked Position Figure 1 CLAMP BOLT Figure 2 Pre-Coating Add the correct amount of D.E. (see specifications on the front page of this manual or on the filter label) into the system through the skimmer - as fast as the plumbing will take it. Record the pressure gauge reading after the D.E. has been added. This is the "pre-coat" or "clean" pressure. OPERATION WARNING FILTERING Filtration starts as soon as the filter has been pre-coated. As the filter removes dirt from the pool water, the accumulated dirt causes a resistance to flow. As a result, the gauge pressure will rise and the flow will decrease. When the pressure rises 8-10 psi (.55-.69 bar) above the pre-coat pressure, it is time to backwash (clean) the filter. Once your filter is running and there is a pressure reading, line up the green arrow with the current reading. (See Fig 3) When the pressure rises to or above the red or second arrow, it is time to clean your filter. Note: During initial clean-up of the pool, particularly with a new pool or a very dirty pool, it may be necessary to backwash more frequently due to the heavy initial dirt load in the water. Figure 3 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Page 5 of 12
Pro-Grid
TM
VERTICAL D.E. SERIES FILTER
ISDE2423 REV C
Manual Air Relief Shown Open
In Locked Position
STARTING THE PUMP and FILTER SYSTEM
WARNING
Before Starting the Pump
1.
Use ONLY Hayward clamp system components; DEX2421JKIT clamp system, DEX2421J2 nut/bolt assembly,
DEX2422Z2 metal reinforced seal. Non-Hayward clamp components may fail in use and cause explosive
component separation.
Verify that upper and lower filter bodies are properly secured with the filter body clamp.
Never rely on hand tightening the clamp nut to the clamp bolt. Using a ¾” socket on a torque wrench, torque clamp
nut to clamp bolt to 150 inch-lbs. Verify that the filter manual air relief body is in the LOCK position, and no filter
components are missing, damaged or not genuine Hayward components.
(See Fig 2)
2. Close filter drain.
Note: Filter plug requires an o-ring seal. (See Fig 4)
3.
Open all system valves to allow water from the pool to the filtration system and from the filter to return to the pool.
4.
Place the manual air relief valve in OPEN position. (See Fig 2)
Starting Pump
1.
When starting system pump, do not stand over or near filter.
If water leakage appears at filter tank clamp,
immediately turn off all system circulation pumps and all electrical power.
Do not return to the filter until all water
leakage has stopped.
Reassemble the clamp system per the instructions on page 7 in this owner’s manual to stop leak.
2.
Return to filter to CLOSE manual air relief valve only when a steady stream of water (not air or, air and water mix) is
discharged from the manual air relief valve.
3.
To avoid damages to the grid elements, DO NOT operate the filter for more than a minute or two without the D.E.
pre-coat.
Pre-Coating
Add the correct amount of D.E. (see specifications on the front page of this manual or on the filter label) into the system
through the skimmer – as fast as the plumbing will take it.
Record the pressure gauge reading after the D.E. has been
added.
This is the “pre-coat” or “clean” pressure.
OPERATION
WARNING
FILTERING
Filtration starts as soon as the filter has been pre-coated.
As the filter removes
dirt from the pool water, the accumulated dirt causes a resistance to flow.
As a
result, the gauge pressure will rise and the flow will decrease.
When the
pressure rises 8-10 psi (.55-.69 bar) above the pre-coat pressure, it is time to
backwash (clean) the filter. Once your filter is running and there is a pressure
reading, line up the green arrow with the current reading. (See Fig 3) When the
pressure rises to or above the red or second arrow, it is time to clean your filter.
Note:
During initial clean-up of the pool, particularly with a new pool or a very
dirty pool, it may be necessary to backwash more frequently due to the heavy
initial dirt load in the water.
CLAMP NUT
CLAMP BOLT
Figure 1
Figure 2
Figure 3
Tighten clamp bolt
and nut using a
torque wrench to
150 inch-lbs.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS