Hayward W3SAS-PRO Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB
Hayward W3SAS-PRO Manual
View all Hayward W3SAS-PRO manuals
Add to My Manuals
Save this manual to your list of manuals |
Hayward W3SAS-PRO manual content summary:
- Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 1
092742 RevB Salt & SwimTM Chlorine Generator for Inground Swimming Pools up to 30,000 gallons Owner's Manual Contents Introduction 1 Installation 2-8 Operation 12-14 Troubleshooting........... 15 Warranty 21 W3SAS-PRO Hayward Pool Products 620 Division Street, Elizabeth NJ 07207 Phone (908)-355- - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 2
risk of electric shock, install at least 10 feet (3 meters) horizontally from the inside walls of a pool or spa/ hot tub. Do not use an extension cord." ATTENTION : MAINTENIR UNE DISTANCE MINIMALE D'UN not smaller than No. 6 AWG. • SAVE THESE INSTRUCTIONS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 3
pool. The Salt & Swim can handle the purification needs of most residential swimming pools up to 30,000 gallons (114,000 liters). This unique low cost chlorine generator uses a replaceable electrolytic Cell (SAS-CELL saline pool with pool pH is discouraged especially in arid regions where pool - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 4
, so start the procedure well before you intend to operate the Salt and Swim. To prepare your pool water, follow the instructions on the included Pool Chemistry Quick Start Guide and refer to page 8 of this manual. Adding Salt: Add salt several hours or, if possible, 1 day prior to operating the - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 5
Box The Salt & Swim is contained in a raintight enclosure that is suitable for outdoor mounting. The Control Box must be mounted a minimum of 10 ft. (4 meters) horizontal distance (or more, if local codes require) from the pool, within 3ft from a GFCI outlet, and within 15ft from where the Cell is - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 6
Vessel. With power removed to the pump and water drained from the pool plumbing, cut the pipe at the desired location. After gluing the Cell Unions on to the cut pipe, position the Vessel in a manner where the Cell can be easily inserted and removed. Secure the Vessel by handtightening the Unions - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 7
Remove the foam protector from the SAS-CELL. Fully cover Cell pins with supplied grease. Verify that the O-ring is attached to the Cell before inserting the Cell into the Cell Vessel as shown. 5 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 8
leaks. Cell Cap Retaining Nut Bonding Pool bonding or "equipotential bonding" ensures that all pool components around the pool are Salt & Swim enclosure. Run an eight gauge (8 AWG) solid copper wire from the bonding lug to your pool's existing bonding loop. to Pool Bonding loop 6 USE ONLY HAYWARD - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 9
Guide as well as the "Water Chemistry" section of this manual for information on how to prepare your pool water for Salt & Swim operation. At start-up, or when a new Cell is installed, the Salt , refer to the Troubleshooting section of this manual. 7 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 10
& Swim chlorine generator. Have your water tested or use pool water test strips and refer to the Chemistry Quick Start Guide information on testing and adjusting your pool's water chemistry. Your Authorized Salt & Swim Dealer or most pool stores can provide you with the chemicals and procedures to - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 11
drain the pool and refill with fresh water. Always check stabilizer (cyanuric acid), when checking salt. These levels will most likely decline together. Use the chart on page 11 to determine how much stabilizer must be added to raise the level to 40 ppm. 9 USE ONLY HAYWARD GENUINE REPLACEMENT - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 12
POUNDS and (Kg) of SALT NEEDED FOR 3200PPM Current salt Gallons and (Liters) of Pool Water level 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000 24,000 25 OK OK OK OK 3600+ Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute 10 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 13
11 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 14
The main controls and indicators are shown below. Illuminates when Cell has reached the end of its expected life. When this LED indicator is illuminated, there is a problem with the unit. Refer to the Troubleshooting section of this manual. Illuminates when unit is waiting for the filter pump to - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 15
the Salt & Swim unless pool components are being serviced or the pool will be closed. When power is first applied to the Salt & Salt & Swim Cell ages. You may need to lower the setting when the pool water temperature decreases significantly or there are long periods of inactivity. 13 USE ONLY HAYWARD - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 16
. In areas where water is hard (high mineral content) and in pools where the water chemistry has been allowed to get "out of balance," the Cell may require periodic cleaning. Servicing and Cleaning the Salt & Swim Cell Unplug the Salt & Swim from the GFCI outlet and remove power from the pump before - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 17
Visit www.hayward.com or call (908)-355-7995 for helpful information on operation, maintenance and troubleshooting your Salt & Swim Electronic Chlorine Generator. Common Problems and Solutions The Salt & Swim's various LEDs show the operation status as well as alert the user to any problems that - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 18
DETECTED LED illuminated AND MIN LED blinking - The salt level may be too low. Adjust salt to recommended levels. - Remove and inspect the Cell for scale. If the Cell is scaled, follow the directions on page 14 for Cell cleaning. 8. PROBLEM DETECTED LED illuminated AND a DAILY CHLORINE OUTPUT - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 19
, follow the Cell cleaning procedure. 3. Check the salt level in the pool and verify the salt level is greater than 2600ppm but also less than 3400ppm. 4. Inspect the Cell Vessel and verify the Cell plates are fully covered by moving water. 5. Contact Hayward Technical Service. LED 3 1. Recycle - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 20
18 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 21
19 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 22
20 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 23
the Hayward Technical Service Support Center (61 Whitecap Road, North Kingstown RI, 02852) or visit the Hayward website at www.hayward.com. WARRANTY EXCLUSIONS: 1. Damage resulting from improper installation including installation on pools larger than the product rating. 2. Problems resulting - Hayward W3SAS-PRO | Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 24
FOR FURTHER INFORMATION OR CONSUMER TECHNICAL SUPPORT, VISIT OUR WEBSITE AT www.hayward.com Hayward is a registered trademark and Salt & Swim is a rademark of Hayward Industries, Inc. © 2019 Hayward Industries, Inc. All other trademarks not owned by Hayward are the property of their respective
Salt & Swim
Chlorine Generator for Inground
Swimming Pools up to 30,000 gallons
TM
Owner’s Manual
W3SAS-PRO
Contents
Introduction
....................
1
Installation
..................
2-8
Operation
.................
12-14
Troubleshooting
...........
15
Warranty
........................
21
Hayward Pool Products
620 Division Street, Elizabeth NJ 07207
Phone (908)-355-7995
www.hayward.com
092742 RevB