Hayward W3SAS-PRO Salt-Swim-Inground-30000-Gallons-Owners-Manual-092742RevB - Page 18

Flow Switch

Page 18 highlights

If the condition persists, remove the Cell from the Vessel and check that the flow switch is free to move in both directions. Refer to the diagram below. Flow Switch 5. CELL LIFE LOW LED illuminated The Cell has reached the end of its life. Replace as soon as possible 6. PROBLEM DETECTED LED illuminated AND MAX LED blinking There is a communication error with the Cell. Check that the Cell cap is properly plugged in and that the wire to the Control Box is not cut or damaged. 7. PROBLEM DETECTED LED illuminated AND MIN LED blinking - The salt level may be too low. Adjust salt to recommended levels. - Remove and inspect the Cell for scale. If the Cell is scaled, follow the directions on page 14 for Cell cleaning. 8. PROBLEM DETECTED LED illuminated AND a DAILY CHLORINE OUTPUT LED is blinking The Salt & Swim may display an error by illuminating the PROBLEM DETECTED LED and blinking one of the DAILY CHLORINE OUTPUT LEDs. There are ten DAILY CHLORINE OUTPUT LEDs that each indicate a different error. These LEDs are labeled with a number on the diagram below. Refer to the table for their corresponding errors. SUPER CHLORINATING GENERATING CHLORINE STANDING BY 67 5 8 9 10 MAX PROBLEM DETECTED 4 3 2 1 S SUPER CHLORINATE USE SUPER CHLORINATE FOR TEMPORARY OUTPUT BOOST DAILY CHLORINE MIN CELL LIFE LOW OUTPUT TEST WATER REGULARLY - SET OUTPUT TO MAINTAIN 1-3 PPM AVERAGE CHLORINE INADEQUATE WATER FLOW 16 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

If the condition persists, remove the Cell from the Vessel and check that the flow switch is free to
move in both directions.
Refer to the diagram below.
5.
CELL LIFE LOW LED illuminated
The Cell has reached the end of its life.
Replace as soon as possible
6.
PROBLEM DETECTED LED illuminated AND MAX LED blinking
There is a communication error with the Cell. Check that the Cell cap is properly plugged in and
that the wire to the Control Box is not cut or damaged.
7.
PROBLEM DETECTED LED illuminated AND MIN LED blinking
-
The salt level may be too low.
Adjust salt to recommended levels.
-
Remove and inspect the Cell for scale.
If the Cell is scaled, follow the directions on page 14 for
Cell cleaning.
8.
PROBLEM DETECTED LED illuminated AND a DAILY CHLORINE OUTPUT LED is
blinking
The Salt & Swim may display an error by illuminating the PROBLEM DETECTED LED and blinking
one of the DAILY CHLORINE OUTPUT LEDs.
There are ten DAILY CHLORINE OUTPUT LEDs that
each indicate a different error.
These LEDs are labeled with a number on the diagram below.
Refer
to the table for their corresponding errors.
Flow Switch
STANDING BY
GENERATING
CHLORINE
SUPER
CHLORINATING
PROBLEM
DETECTED
CELL LIFE LOW
INADEQUATE
WATER FLOW
TEST WATER REGULARLY - SET OUTPUT TO
MAINTAIN 1-3 PPM AVERAGE CHLORINE
SUPER
CHLORINATE
MIN
MAX
USE SUPER CHLORINATE
FOR TEMPORARY OUTPUT BOOST
DAILY CHLORINE
OUTPUT
1
2
3
4
5
6
7
8
9
10
S
16
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS