Mounting the Salt & Swim Control Box, Plumbing

Page 5 highlights

Mounting the Salt & Swim Control Box The Salt & Swim is contained in a raintight enclosure that is suitable for outdoor mounting. The Control Box must be mounted a minimum of 10 ft. (4 meters) horizontal distance (or more, if local codes require) from the pool, within 3ft from a GFCI outlet, and within 15ft from where the Cell is installed. The Control Box is designed to mount vertically on a flat surface with the cables facing downward. Because the enclosure also acts as a heat sink (disperses heat from inside the box), it is important not to block the four sides of the Control Box. Do not mount Salt & Swim inside a panel or tightly enclosed area. Before securing the Control Box to the intended location, make sure that the power cord will reach the GFCI outlet and that the Cell cable will reach the location where the Cell Vessel will be installed. Refer to the diagram below. Screw in top fasteners leaving 1/8" space between Hang Control screw head and surface on fasteners Screw in bottom fasteners securely. Plumbing The Cell Vessel is designed to install in 2" PVC pool plumbing only. The Cell Vessel must be installed on a 11.5" run of straight pipe at the end of the return piping just before the water returns to the pool. All pool equipment should be upstream from the Cell Vessel. It must be located within 15 feet of where the Control Box is mounted. Also, there must be enough clearance to insert and remove the Cell from the Vessel after the Vessel is installed. 3 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Mounting the Salt & Swim Control Box
The Salt & Swim is contained in a raintight enclosure that is suitable for outdoor mounting.
The Control
Box must be mounted a minimum of 10 ft. (4 meters) horizontal distance (or more, if local codes
require) from the pool, within 3ft from a GFCI outlet, and within 15ft from where the Cell is installed.
The Control Box is designed to mount vertically on a flat surface with the cables facing downward.
Because the enclosure also acts as a heat sink (disperses heat from inside the box), it is important
not to block the four sides of the Control Box.
Do not mount Salt & Swim inside a panel or tightly
enclosed area.
Before securing the Control Box to the intended location, make sure that the power cord will reach
the GFCI outlet and that the Cell cable will reach the location where the Cell Vessel will be installed.
Refer to the diagram below.
Plumbing
The Cell Vessel is designed to install in 2" PVC pool plumbing only.
The Cell Vessel must be installed
on a 11.5" run of straight pipe at the end of the return piping just before the water returns to the
pool.
All pool equipment should be upstream from the Cell Vessel.
It must be located within 15 feet
of where the Control Box is mounted.
Also, there must be enough clearance to insert and remove
the Cell from the Vessel after the Vessel is installed.
Screw in top
fasteners leaving
1/8” space between
screw head and surface
Hang Control
on fasteners
Screw in bottom fasteners securely.