HP 1606 FICON Administrator's Guide v6.4.0 (53-1001771-01, June 2010) - Page 30
command on the switch you want to be the principal switch., In cascaded fabrics
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
2 Configuring switched point-to-point FICON TABLE 2 FICON switch parameters (Continued) Parameter Response Comment Per-frame route priority 0 Long-distance fabric 0 BB credit 16 Insistent Domain ID mode Yes Virtual Channel parameters No F-Port login parameters No Maximum logins per switch Maximum logins per port Maximum logins per second Login stage interval Zoning operation parameters No RSCN transmission mode No Arbitrated Loop parameters No System services No Portlog events enable No SSL attributes No RPCD attributes No cfgload attributes No Web Tools attributes No System No Do not change. Do not change. The recommended best practice is to configure individual ports for long distance when cascading at extended distances. Do not change. This parameter has been deprecated. BB credit settings should be set on a per port basis. Recommended best practice is to set the domain ID to be insistent. Setting the insistent domain ID is required for 2-byte addressing. Do not change. With FOS 6.1.0 and later it is not necessary to make any changes to F_Port login parameters. The only other reason to answer yes (y) to this prompt is if NPIV is being used and there is a need to change the default number of NPIV logins. Change this only if NPIV is being used and the number of fabric logins will exceed the default or there is a need to limit the number of logins. Change this only if NPIV is being used and the number of port logins will exceed the default or there is a need to limit the number of logins. FOS 6.1.0b and later - Do not change. Leave at default. NOTE: The default value is incorrectly shown as 0. Do not change. 9. Enter the switchEnable command to set the switch online. 10. Enter the trackChanges command to track all changes. If not set, only changes deemed errors are logged. 11. Enter the fabricPrincipal command on the switch you want to be the principal switch. In cascaded fabrics, only one switch should be principal. In core-edge designs, the director class switch should be principle. 18 FICON Administrator's Guide 53-1001771-01