HP 1606 HP StorageWorks Fabric OS 6.3.2b Release Notes (5697-0777, November 20 - Page 35

The disable EE interface CLI, Fabric OS 6.3.1a.

Page 35 highlights

changes being applied to only a subset of the encryption switches in the encryption group. This was a rare situation that had only been seen in test environments. This issue has been resolved in Fabric OS 6.3.1a. • If the data encryption group (Encryption Group) gets into a state where the Group Leader encryption switch reports that another encryption switch is NOT a member node of the encryption group, and the encryption switch member node still indicates that it IS part of the encryption group, the following recovery action can be performed to re-merge the nodes into the encryption group: 1. On the Group Leader encryption switch, execute the CLI command cryptocfg -dereg -membernode 2. Wait for 30 seconds. 3. Execute the CLI command cryptocfg -reg -membernode This is a rare situation that has been noted in a test environment where there were intermittent management network connectivity problems. A fix for this issue is in the Fabric OS 6.4.0 release. • To remove access between a given initiator and target, the user must not only remove the active zoning information between the initiator and target, but must also remove the associated CTCs, which will in turn remove the associated frame redirection zone information. Make sure to back up all data before taking this action. • Before committing configurations or modifications to the CTC or LUNs on an HP Encryption Switch or HP Encryption Blade, make sure that there are no outstanding zoning transactions in the switch or fabric. Failure to do so results in the commit operation for the CTC or LUNs failing and may cause the LUNs to be disabled. The user can check for outstanding zoning transactions by issuing the CLI command cfgtransshow: DCX_two:root> cfgtransshow There is no outstanding zoning transaction • Each LUN is uniquely identified by the HP Encryption Switch or HP Encryption Blade using the LUN's serial number. The LUN serial numbers must be unique for LUNs exposed from the same target port. The LUN serial numbers must also be unique for LUNs belonging to different target ports in nonmultipathing configurations. Failure to ensure unique LUN serial numbers results in nondeterministic behavior and may result in faulting of the HP Encryption Switch or HP Encryption Blade. • When creating an HA cluster or EG with two or more HP Encryption Switch/Encryption Blades, the GE ports (I/O sync links) must be configured with an IP address for the eth0 and eth1 Ethernet interfaces using ipaddrset. In addition, the eth0 and eth1 Ethernet ports should be connected to the network for redundancy. These I/O sync links connections must be established before any Re-Key, First Time Encryption, or enabling EE for crypto operations. Failure to do so results in HA Cluster creation failure. If the IP address for these ports is configured after the EE was enabled for encryption, HP Encryption Switch needs to be rebooted and Encryption Blades should be slotpoweroff/slotpoweron to sync up the IP address information to the EEs. If only one Ethernet port is configured and connected to a network, data loss or suspension of Re-Key may occur when the network connection toggles or fails. • initEE will remove the existing master key or link key. Backup the master key by running cryptocfg -exportmasterkey and cryptocfg -export -currentMK before running initEE. After initEE, regEE and enableEE, run cryptocfg -recovermasterkey to recover the master key previously backed up, or in the case of fresh install run cryptocfg - genmasterkey to generate a new master key. If you are using SKM, establish a trusted link with SKM again. Certificate exchange between key vaults and switches are not required in this case. • The disable EE interface CLI cryptocfg --disableEE [slot no] should be used only to disable encryption and security capabilities of the EE from the Fabric OS Security Admin in the event of a security compromise. When disabling the encryption capabilities of the EE using the HP StorageWorks Fabric OS 6.3.2b Release Notes 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

changes being applied to only a subset of the encryption switches in the encryption group. This
was a rare situation that had only been seen in test environments. This issue has been resolved in
Fabric OS 6.3.1a.
If the data encryption group (Encryption Group) gets into a state where the Group Leader encryption
switch reports that another encryption switch is NOT a member node of the encryption group,
and the encryption switch member node still indicates that it IS part of the encryption group, the
following recovery action can be performed to re-merge the nodes into the encryption group:
1.
On the Group Leader encryption switch, execute the CLI command
cryptocfg –dereg
–membernode <WWN of member node>
2.
Wait for 30 seconds.
3.
Execute the CLI command
cryptocfg –reg –membernode <WWN membernode>
<certificate file name> <ipaddr of member node>
This is a rare situation that has been noted in a test environment where there were intermittent
management network connectivity problems. A fix for this issue is in the Fabric OS 6.4.0 release.
To remove access between a given initiator and target, the user must not only remove the active
zoning information between the initiator and target, but must also remove the associated CTCs,
which will in turn remove the associated frame redirection zone information. Make sure to back
up all data before taking this action.
Before committing configurations or modifications to the CTC or LUNs on an HP Encryption Switch
or HP Encryption Blade, make sure that there are no outstanding zoning transactions in the switch
or fabric. Failure to do so results in the commit operation for the CTC or LUNs failing and may
cause the LUNs to be disabled. The user can check for outstanding zoning transactions by issuing
the CLI command
cfgtransshow
:
DCX_two:root> cfgtransshow
There is no outstanding zoning transaction
Each LUN is uniquely identified by the HP Encryption Switch or HP Encryption Blade using the
LUN
s serial number. The LUN serial numbers must be unique for LUNs exposed from the same
target port. The LUN serial numbers must also be unique for LUNs belonging to different target
ports in nonmultipathing configurations. Failure to ensure unique LUN serial numbers results in
nondeterministic behavior and may result in faulting of the HP Encryption Switch or HP Encryption
Blade.
When creating an HA cluster or EG with two or more HP Encryption Switch/Encryption Blades,
the GE ports (I/O sync links) must be configured with an IP address for the
eth0
and
eth1
Ethernet
interfaces using
ipaddrset
. In addition, the
eth0
and
eth1
Ethernet ports should be connected
to the network for redundancy. These I/O sync links connections must be established before any
Re-Key, First Time Encryption, or enabling EE for crypto operations. Failure to do so results in HA
Cluster creation failure. If the IP address for these ports is configured after the EE was enabled for
encryption, HP Encryption Switch needs to be rebooted and Encryption Blades should be
slot-
poweroff
/
slotpoweron
to sync up the IP address information to the EEs. If only one Ethernet
port is configured and connected to a network, data loss or suspension of Re-Key may occur when
the network connection toggles or fails.
initEE
will remove the existing master key or link key. Backup the master key by running
cryptocfg –exportmasterkey
and
cryptocfg –export –currentMK
before running
initEE
. After
initEE
,
regEE
and
enableEE
, run
cryptocfg –recovermasterkey
to re-
cover the master key previously backed up, or in the case of fresh install run
cryptocfg –
genmasterkey
to generate a new master key. If you are using SKM, establish a trusted link with
SKM again. Certificate exchange between key vaults and switches are not required in this case.
The disable EE interface CLI
cryptocfg --disableEE [slot no]
should be used only to
disable encryption and security capabilities of the EE from the Fabric OS Security Admin in the
event of a security compromise. When disabling the encryption capabilities of the EE using the
HP StorageWorks Fabric OS 6.3.2b Release Notes
35