HP 1606 HP StorageWorks Fabric OS 6.3.2b Release Notes (5697-0777, November 20 - Page 43
Rolling asserts occur on 4/256 SAN Director with Multiprotocol Router
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
WWN PID static binding was setup on the switch using the wwnaddress -bind command and WWN_A is bound to PID A, and WWN_B is bound to PID B. Almost instantaneously, both ports go offline due to a device "rebalance" and, when the links come back up, WWN to PID binding is swapped. Ports become disabled with the reason Disabled (PPID set on device, other port online with area). Fixed in Fabric OS 6.3.2. As a result of an external FC port on the encryption SAN switch or blade experiencing an excessive number of encoding CRC errors, the internal ports are faulted incorrectly by switch firmware. This leads to a data encryption virtual initiator associated with the internal port failing to appear in the name server. Workaround prior to upgrade: Remove the condition/cause of the excessive CRC errors (that is, replace cable or SFP). Fixed in Fabric OS 6.3.2. Rolling asserts occur on 4/256 SAN Director with Multiprotocol Router blade, or on 400 Multiprotocol Router when attempting to connect to an encryption SAN switch via EX_Port. Workaround prior to upgrade: Disable the E_Port on the encryption switch to recover the switch. Fixed in Fabric OS 6.3.2. PLOGI ACC is dropped when there is back-to-back plogin to a well- known address such as msd, nsd, fabric controller, etc., before the switch route setup is completed. The PLOGIs are held in queue without being ACC'd until the route setup is completed, but the issue is that once the setup is done, only one of the PLOGIs is ACC'd and the rest are dropped. Applies to any switch running 6.x Fabric OS, but more likely in directors. This is an unlikely scenario, because most devices do not perform such back-to-back logins early during switch/fabric bring up. Fixed in Fabric OS 6.3.2. During a stress test where interface toggling was triggered while a login is pending, a kernel panic occurred on the 2408 FCoE switch or 10/24 Fixed in Fabric OS 6.3.2. FCoE blade. When F_Port trunking is activated and after the master trunk goes offline, the switch adds the new master trunk to the list of ports, which will send EFP/BF/DIA flood. The ports remain in this state until all N_Ports are taken offline and logged back into the fabric again. Build Fabric (BF) is sent to the AG. AG forwarding the BF to redundant fabric caused fabric disruption. Fixed in Fabric OS 6.3.2. iSCSI director blade iscsicfg -commit all hangs the switch Telnet Fixed in Fabric OS 6.3.2. session, and hafailover is needed to recover. Weblinker terminated while removing slot-based license. 1. Open the switch via http and get into the licenseadmin page, Switchadmin -> licenseadmin. 2. Remove the Advanced extension slot based license. Weblinker is terminated. The daemon is restarted without further functional impact. Fixed in Fabric OS 6.3.2. With VF disabled, aborts and timeouts were seen on traffic over FCIP of FID 128 when Port Based Route Policy (aptpolicy of 1) was not propagated from CP to DP properly. Fixed in Fabric OS 6.3.2. HP StorageWorks Fabric OS 6.3.2b Release Notes 43