HP 3PAR StoreServ 7200 2-node HP 3PAR StoreServ 7000 Storage Service Guide - Page 34

I/O Modules LEDs, Drive PCM LEDs, Table 4 Drive PCM LED Descriptions

Page 34 highlights

Figure 31 Drive PCM LEDs Table 4 (page 34) describes the drive PCM LED states. Table 4 Drive PCM LED Descriptions Icon LED Appearance On AC input fail Amber Flashing PCM OK Green On Flashing Indicates No AC power or PCM fault FiPartner PCM Faulty/Off or Firmware Download AC Present and PCM On / OK Standby mode Fan Fail Amber On Flashing PCM fail or PCM fault Firmware download DC Output Fail Amber On Flashing No AC power or fault or out of tolerance Firmware download I/O Modules LEDs I/O modules are located on the back of the system. I/O modules have two mini-SAS universal ports, which can be connected to HBAs or other ports and each port includes External Port Activity LEDs, labeled 0-3. The I/O module also includes a Power and Fault LED (see Figure 32 (page 34), Figure 33 (page 35), and Table 5 (page 35)). Figure 32 M6710 I/O Module 34 Understanding LED Indicator Status

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65

Figure 31 Drive PCM LEDs
Table 4 (page 34)
describes the drive PCM LED states.
Table 4 Drive PCM LED Descriptions
Indicates
Appearance
LED
Icon
No AC power or PCM fault
On
Amber
AC input fail
FiPartner PCM Faulty/Off or Firmware
Download
Flashing
AC Present and PCM On / OK
On
Green
PCM OK
Standby mode
Flashing
PCM fail or PCM fault
On
Amber
Fan Fail
Firmware download
Flashing
No AC power or fault or out of tolerance
On
Amber
DC Output Fail
Firmware download
Flashing
I/O Modules LEDs
I/O modules are located on the back of the system. I/O modules have two mini-SAS universal
ports, which can be connected to HBAs or other ports and each port includes External Port Activity
LEDs, labeled 0–3. The I/O module also includes a Power and Fault LED (see
Figure 32 (page
34)
,
Figure 33 (page 35)
, and
Table 5 (page 35)
).
Figure 32 M6710 I/O Module
34
Understanding LED Indicator Status