HP 3PAR StoreServ 7450 4-node HP 3PAR OS 3.1.2 Release Notes - Page 40
on the HP 3PAR StoreServ 7000 Storage system., primary storage system. In HP 3PAR OS 3.1.2
View all HP 3PAR StoreServ 7450 4-node manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
Issue ID 84307 84353 84384 84500 85608 85797 85947 86094 86127 86441 Item Description Resolved licensing issue on post-ootb pre-license When HP 3PAR StoreServ 7000 Storage system install wipe. is not built to order it means that it is shipped with a license for 8 disks. If such a system goes through the ootb process to create the admin volume but the process is restarted before the actual license key is installed, it does not admit disks on the second attempt until the license key is removed manually. This is resolved. The disks can be admitted in this situation. kernel error message is displayed when dismissrcopytarget command is issued. The remote copy group must be stopped to ALL targets before issuing the dismissrcopytarget command or a kernel error message is displayed. Several issues with CIM API resolved. The following issues, found while testing with client partners, are resolved: 1. ReturnToStoragePool does not remove the underlying logical disks of the StorageVolume. 2. ExposePaths with multiple InitiatorPortIDs results in multiple instances of SPC, one for each InitiatorPortID. This is resolved. All the InitiatorPortIDs belong to the same SPC. 3. There are no fixed StorageSetting that can be used for creating DynamicStoragePool from primoridal InExtents. This is resolved. StorageSettings are added, one for each supported RAID type. CIM API - ExposePaths fails to map volumes to a host. TPD_ControllerConfigurationService.ExposePaths() fails to map several volumes to a host. ExposePaths() incorrectly reports that some of the volumes belong to a different domain even if all the volumes are in the same domain, as reported by showvv -listdom command. This is resolved. The command Upgradecage sometimes fails with 3502 error. The command Upgradecage of DCS1, DCS2, and DCN1 cages can fail sometimes due to a timing issue and a 3502 error is displayed. This is resolved and the operation is tried again in case of failure. Improve upgradecage failure error. Improved error message for upgradecage errors on the HP 3PAR StoreServ 7000 Storage system. Kernel error occurs when issuing dismissrcopytarget on SLD system. It is necessary to stop both targets on an SLD system before dismissing a secondary (periodic) target. Failure to do this can result in error on the primary storage system. In HP 3PAR OS 3.1.2 MU2, this criteria is enforced so that the user receives an error message if both targets are not stopped. When a tunesys task is cancelled, a new task may not start for an long period of time. The cancellation of a tunesys task during the initial analysis phase on a system with a large number of base volumes can result in tunesys being unable to restart for a long period of time (over 2 hours in some cases). This issue is resolved. Microsoft Windows 2012 PowerShell cmdlet New-MaskingSet -FriendlyName fails to set friendly name. Microsoft Windows 2012 PowerShell cmdlet New-MaskingSet -FriendlyName fails to set friendly name because ModifyInstance of SPC ElementName is not supported. This is resolved. Earlier cage PCM Alerts remain after system power cycle. If a PCM issue on a DCS1, DCS2, or DCN1 cage generates an alert, and the issue is then resolved 40 HP 3PAR OS 3.1.2 MU2 Release Notes