HP 3PAR StoreServ 7450 4-node HP 3PAR OS 3.1.2 Release Notes - Page 45
Modifications to the HP 3PAR CIM API, Allows ModifyInstance of ElementName
View all HP 3PAR StoreServ 7450 4-node manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
Issue ID 81685 81925 82106 82107 82303 82826 83219 84384 84500 86127 Item Description SMI-S Provider initialization fails if array has an SMI-S provider fails if array has an all-numeric all-numeric name. name (the name as shown in showsys). This is resolved. Resolved an issue where calling Resolved an issue where calling HideLUsFromStorageHardwareIDCollection HideLUsFromStorageHardwareIDCollection results results in occasional "Invalid ProtocolControllers" in occasional "Invalid ProtocolControllers" failure. failure. Both output Job and TargetElement parameters are NULL when calling CreateElementReplica, but without specifying the input TargetElement parameter, to create a clone. After calling CreateElementReplica, without specifying the input TargetElement parameter to create a clone, the output Job and TargetElement parameters are both NULL. The corresponding TPD_ConcreteJob instance is also missing. This is resolved. ModifySynchronization/ ModifySynchronization/ ModifyReplicaSynchronization Resync operation ModifyReplicaSynchronization Resync operation on an asynchronous clone results in target on an asynchronous clone results in target volume volume getting detached getting detached after the resynchronization. This is resolved. RAID level information is included in ElementName of fixed StorageSetting. RAID level information is added to ElementName string of StorageSetting that has ChangeableType of "Fixed - Not Changeable" (0). Resolved an issue where TPD_CreateConsistentReplicaList, CreateGroupReplica, or TPD_CreateGroupReplica resulted in RO snapshots. Resolved an issue where calling TPD_CreateConsistentReplicaList, CreateGroupReplica, or TPD_CreateGroupReplica resulted in read-only snapshots. Occasional failure in generating CIM indications Provider might fail to generate CIM indications. This is due to IndicationProvider not properly loaded during startup. Also, removing a IndicationSubscription may cause failure due to namespace case issue, a known OpenPegasus issue. This is resolved. Several issues with CIM API resolved. The following issues, found while testing with client partners, are resolved: 1. ReturnToStoragePool did not remove the underlying logical disks of the StorageVolume. 2. ExposePaths with multiple InitiatorPortIDs incorrectly resulted in multiple instances of SPC, one for each InitiatorPortID. All the InitiatorPortIDs belong to the same SPC. 3. There were no fixed StorageSetting's that can be used for creating DynamicStoragePool from primoridal InExtents. They are added, one for each supported RAID type. 4. Allows ModifyInstance of ElementName of SCSIProtocolController (only for host-see and matched set vluns). The corresponding host name is modified as a result. ExposePaths fails to map volumes to a host TPD_ControllerConfigurationService.ExposePaths() failed to map several volumes to a host. ExposePaths() incorrectly reports that some of the volumes belong to a different domain even if all the volumes are in the same domain, as reported by showvv -listdom.. This is resolved. Win2012 PowerShell cmdlet New-MaskingSet Win2012 PowerShell cmdlet New-MaskingSet -FriendlyName fails to set friendly name -FriendlyName fails to set friendly name. This is Modifications to the HP 3PAR CIM API 45