HP 4400 HP StorageWorks controller enclosure 4Gb array controller with embedde - Page 1
HP 4400 Manual
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
HP StorageWorks controller enclosure 4Gb array controller with embedded switch replacement instructions These instructions apply to the EVA4400 product family. About this document This document provides the procedure for replacing an HSV300-S controller module (with a B-series embedded switch) in the controller enclosure used with the EVA4400. For the latest documentation, go to http://www.hp.com/support/manuals, and select your product. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. WARRANTY STATEMENT: To obtain a copy of the warranty for this product, see the warranty information website: http://www.hp.com/go/storagewarranty Before you begin Observe the following precautions when replacing a controller. © Copyright 2008, 2009 Hewlett-Packard Development Company, L.P. First edition: February 2009 The information in this document is subject to change without notice. Printed in Puerto Rico www.hp.com CAUTION: HP recommends that you perform the replacement procedure within seven minutes from when the controller is removed to when it is replaced in the enclosure. Ensure all necessary parts are available so the procedure can be completed without interruption. Removing a controller module significantly changes the air flow within the enclosure. Both controllers must be installed for the enclosure to cool properly. If a controller fails, leave it in place in the enclosure until a new module is available to install. The enclosure could shut down due to overheating unless the controller is replaced within the recommended seven minutes. Parts can be damaged by electrostatic discharge. Use proper anti-static protection. Refer to the documentation that shipped with your system for additional information. NOTE: • Alloy (gray)-colored latches on components like the controller means the component is warm-swappable. Halt the I/O of the failing controller with HP Command View EVA before removing this component. • Ensure that the backup configuration settings and correct firmware version of the embedded switch are available to restore or install in a replacement controller. Attempt to save a backup of your switch configuration file if you have not previously done so. • There are two controllers at the rear of the controller enclosure. See Figure 1 for the locations. *533475-001* Page 1