HP StorageWorks 60 Modular Smart Array Enclosure User Guide November 2006 (Second Edition) Part Number 405868-002 - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 2
(Second Edition) Part Number 405868-002 Audience assumptions This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 3
SAS cabling guidelines ...21 Supported cables ...21 Power cords...22 Updating firmware ...22 Hardware options installation...23 Hard drive options ...23 SAS and SATA hard drive guidelines 23 SAS or SATA hard drive...23 Configuration and utilities ...25 Configuration tools ...25 Array Configuration - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 4
Remote support and analysis tools ...27 Open Services Event Manager ...27 Keeping the system current ...27 Change control and proactive notification 27 Care Pack ...27 Troubleshooting ...28 When the storage enclosure does not start 28 Diagnostic questions ...29 Are the power supply/system fan LEDs - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 5
Index...51 Contents 5 - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 6
Rear panel LEDs and buttons ...8 SAS and SATA device numbers ...9 SAS and SATA hard drive LEDs ...9 SAS and SATA hard drive LED combinations 9 Front panel LEDs and buttons Item Description Status 1 Heartbeat LED Green = System activity Off = No system activity 2 Fault LED Amber = Fault - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 7
board (for box ID numbering) 4 SAS in connector 5 SAS out connector 6 I/O module bay 7 For future use 8 Fan module 2 9 Power supply 2 Dual 7-segment display board The dual 7-segment display board displays the host controller-assigned port and box ID number for the MSA60 to which it is - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 8
condition Off = No fault condition 6 Power On/Standby Green = On button/system power Amber = Standby (auxiliary power present) LED Off = Off 7 Power supply LED Green = Power turned on and power supply functioning properly Amber flashing = Standby (auxiliary power present) Off = One or more - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 9
SAS and SATA device numbers SAS and SATA hard drive LEDs Item Description 1 Fault/UID LED (amber/blue) 2 Online LED (green) SAS and SATA hard drive LED combinations NOTE: Predictive failure alerts can occur only when the storage enclosure is connected to a Smart Array controller. Component - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 10
for this drive and the controller has placed it offline. Replace the drive as soon as possible. A predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is offline, a spare, or not configured as part of an array. Component identification - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 11
connected host controller can identify and configure them at power up. • Always power up the storage enclosure first, and then the server. To power up the storage enclosure: 1. Complete server hardware installation and cabling. See the server documentation. 2. Connect the SAS cables and power cords - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 12
2. Press the Power On/Standby button on the storage enclosure. Wait for the system power LED to go from green to amber. 3. Disconnect the power cords. The system is now without power. Operations 12 - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 13
a storage enclosure into the rack 17 Installing hardware options ...19 Installing servers...19 Choosing a configuration...20 Cabling the storage enclosure ...21 Updating firmware ...22 Rack planning resources The rack resource kit ships with all HP branded 10000 series racks. For more information - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 14
in installations covered by NFPA 70, 1999 Edition (National Electric Code) and NFPA-75, 1992 (code for Protection of Electronic Computer/Data Processing Equipment). For electrical power ratings on options, refer to the product rating label or the user documentation supplied with that option. WARNING - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 15
of the rack when it is rolling down the ramp from the pallet. Always handle the rack from both sides. Shipping contents When unpacking the MSA60, locate the following items: • MSA60 • Rack mounting hardware kit • Power cords (2) • SAS cable • Documentation kit Setup 15 - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 16
30.00 in). If you are installing the MSA60 in an M-Series rack, contact an authorized reseller to obtain an M-Series Rack Rail option kit. Item Description 1 Rack rail (left) 2 Rack rail (right) 3 Pins for round-hole rack conversion (8) In addition to these supplied items, you may need a No - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 17
and 4 for the second rail. Installing a storage enclosure into the rack To install the storage enclosure into the rack: 1. Secure the front end of the rails to the rack. IMPORTANT: Do not remove the pins from the ends of the rack rails unless you are converting the rails for use in round-hole racks - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 18
the storage enclosure for shipping: IMPORTANT: Use of the shipping bracket is required only when the rack is shipped with the MSA60 installed. a. Loosen the thumbscrew on the shipping bracket. b. Slide the shipping bracket forward until it engages the chassis. c. Tighten the thumbscrew. Setup 18 - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 19
-specific instructions on the website to install the rack brackets. Use the following information when connecting peripheral cables and power cords to the storage enclosure. Item Description 1 Power supply 1 2 Fan module 1 3 Dual 7-segment display board (for box ID numbering) 4 SAS - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 20
I/O module is for input from the server. The right connector of the I/O module is for output to another storage enclosure. See the icons on the cables and enclosure to assist in proper connection. Single-enclosure configuration Item Description 1 MSA60 2 SAS cable 3 Server Setup 20 - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 21
• 1+3 configuration for a total of four cascading enclosures Cabling the storage enclosure After installing the storage enclosure in a rack, connect the SAS cables and power cords to the rear panel. SAS cabling guidelines Observe the following guidelines: • Only use supported SAS cables with 3-Gb - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 22
HP website (http://www.hp.com/support). After installing hardware and powering up the storage enclosure for the first time, be sure to verify that the host controllers and drives have the latest firmware. For firmware and software updates, refer to the HP website (http://h18004.www1.hp.com/support - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 23
only one hard drive is used, install it in the bay with the lowest device number. • Drives must be the same capacity to provide the greatest storage space efficiency when drives are grouped together into the same drive array. NOTE: ACU does not support mixing SAS and SATA drives in the same logical - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 24
drive. 3. Install the hard drive. IMPORTANT: When the drive is inserted, the drive LEDs flash for 2 seconds to indicate that the drive is seated properly and receiving power. 4. Determine the status of the hard drive from the SAS and SATA hard drive LED combinations. Hardware options installation - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 25
Array Controllers Reference Guide on the Documentation CD or the HP website (http://www.hp.com). Option ROM Configuration for Arrays Before installing an operating system, you can use the ORCA utility to create the first logical drive, assign RAID levels, and establish online spare configurations - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 26
the software and drivers page for storage products (http://www.hp.com/support/proliantstorage). 1. Find the most recent version of the component that you require. Components for controller firmware updates are available in offline and online formats. 2. Follow the instructions for installing the - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 27
• From within HP Insight Diagnostics For more information, refer to the Management CD in the HP ProLiant Essentials Foundation Pack. Array Diagnostic Utility The HP Array Diagnostics Utility is a web-based application that creates a report of all HP storage controllers and disk drives. This report - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 28
working properly. Check the status using the power supply LEDs ("Rear panel LEDs and buttons" on page 8). 4. Remove the AC power cords from both enclosure power supplies and reinsert them. 5. Restart the system. IMPORTANT: If the system does not restart, proceed to "Diagnostic questions (on page 29 - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 29
hard drives: • The amber LED on the front of a storage system is lit if drives fail. (However, this LED also illuminates when other problems occur, such as when a system fan fails, a redundant power supply fails, or the system overheats.) • ACU represents failed drives with a distinctive icon. • HP - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 30
while another drive in the array is being rebuilt. If the array has no online spare, any logical drives in this array that are configured with RAID 5 fault tolerance will fail. Compromised fault tolerance can also be caused by non-drive problems, such as a faulty cable or temporary power loss to - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 31
data loss. • In RAID 6 with ADG configurations, any two drives in the array can be replaced simultaneously. Automatic data recovery (rebuild) When you replace a hard drive in an array, the controller uses the fault-tolerance information on the remaining drives in the array to reconstruct the missing - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 32
If the Online LED of the replacement drive stops blinking and the amber Fault LED glows, or if other drive LEDs in the array go out, the replacement drive has failed and is producing unrecoverable disk errors. Remove and replace the failed replacement drive. When automatic data recovery has finished - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 33
controller was configured with hardware fault tolerance, complete the following steps after a disk drive failure: 1. Determine which physical drive failed. On hot-plug drives, an amber drive failure LED illuminates. 2. If the unit containing the failed drive does not support hot-plug drives, perform - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 34
by users in private households in the European Union 37 Japanese notice ...37 BSMI notice ...37 Korean notice ...38 Power cord statement for Japan ...38 Regulatory compliance identification numbers For the purpose of regulatory compliance certifications and identification, this product has - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 35
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 36
: This marking is valid for non-Telecom products and EU harmonized Telecom products (e.g. Bluetooth). This marking is valid for EU non-harmonized Telecom products. *Notified body number (used only if applicable-refer to the product label) Hewlett-Packard GmbH, HQ-TRE, Herrenberger Strasse 140, 71034 - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 37
of waste equipment by users in private households in the European Union This symbol on the product or on its packaging indicates that this product must not be , your household waste disposal service or the shop where you purchased the product. Japanese notice BSMI notice Regulatory compliance notices - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 38
Korean notice Class A equipment Class B equipment Power cord statement for Japan Regulatory compliance notices 38 - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 39
field service tools. • Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part. For more information on static electricity or assistance with product installation - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 40
to 90% relative humidity (Rh), 28º C (82.4º F) maximum wet bulb temperature, non-condensing 5% to 95% relative humidity (Rh), 38.7º C (101.66º F) maximum wet bulb temperature, non-condensing 3048 m (10,000 ft) This value may be limited by the type and number of options installed. 9144 m (30, 000 ft - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 41
• Product model name and number • Applicable error messages • Add-on boards or hardware • Third-party hardware or software • Operating system type and revision level HP contact information For the name of the nearest HP authorized reseller: • In the United States, see the HP US service locator - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 42
customer self repair is optional. These parts are also designed for customer self repair. If, however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product. NOTE: Some HP parts are not designed for - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 43
comportare la fatturazione del ricambio da parte di HP. Nel caso di riparazione da parte del cliente, HP sostiene tutte le spese di HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen Service berechnet. • Optional - Teile, für die das Customer Self Repair-Verfahren optional - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 44
gbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen Obligatorio: componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a HP que realice la sustitución de estos componentes, tendr - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 45
HP (of een HP Service product. OPMERKING: Sommige HP HP. Informatie over Service Partners vindt u op de HP website (http://www.hp.nl/services/servicepartners). Reparo feito pelo cliente Os produtos da HP HP (ou fornecedores/parceiros de serviço da HP desejar que a HP substitua essas a HP as substitua - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 46
técnico da HP para que um técnico o ajude por telefone. A HP especifica nos materiais HP. Nos casos em que isso for necessário, é preciso enviar a peça com defeito à HP HP poderá cobrar a reposição. Para as peças de reparo feito pelo cliente, a HP feito pelo cliente da HP, entre em contato com o fornecedor - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 47
Technical support 47 - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 48
Technical support 48 - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 49
ACU Array Configuration Utility ADG Advanced Data Guarding (also known as RAID 6) ADU Array Diagnostics Utility CSA Canadian Standards Association HBA host bus adapter IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IML Integrated Management Log - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 50
Fire Protection Association ORCA Option ROM Configuration for Arrays OSEM Open Services Event Manager PSP ProLiant Support Pack RAID redundant array of inexpensive (or independent) disks RBSU ROM-Based Setup Utility SAS serial attached SCSI SATA serial ATA SCSI small computer system interface - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 51
Pack 26 HP Systems Insight Manager, overview 26 HP technical support 41 I IML (Integrated Management Log) 26 installation, server options 23 Integrated Management Log (IML) 26 J Japanese notice 37 K kit contents 15 Korean notices 38 L LEDs 6, 9 LEDs, troubleshooting 9, 28 M Management Agents 26 - HP 60 | HP StorageWorks 60 Modular Smart Array Enclosure User Guide - Page 52
O Open Services Event Manager 27 optimum environment 13 Option ROM Configuration for Arrays (ORCA) 25 options installation 23 ORCA (Option ROM Configuration for Arrays) 25 P phone numbers 41 power cord 22, 38 power requirements 14 powering up 11 problem diagnosis 28 R rack installation 15 rack
HP StorageWorks 60 Modular
Smart Array Enclosure
User Guide
November 2006 (Second Edition)
Part Number 405868-002