HP 6400/8400 HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack
HP 6400/8400 Manual
View all HP 6400/8400 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP 6400/8400 manual content summary:
- HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 1
HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide This guide describes how to add an expansion rack to an EVA6400/8400 main rack and is intended for HP-authorized service personnel only. Part number: 5697-8184 First edition: September 2009 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 3
up the controllers 42 4 Support and other resources 45 Contacting HP ...45 HP technical support ...45 Subscription service ...45 Documentation feedback ...45 Related information ...45 Documents ...45 Websites ...46 HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 3 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 4
Typographic conventions ...46 Customer self repair ...47 Rack stability ...47 4 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 5
38 28 EVA8400 0C9D loop 2 connections 39 29 EVA8400 0C9D loop 3 connections 40 30 Complete cabling for an EVA8400 2C18D to 0C9D expansion (2C27D 41 HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 5 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 6
Tables 1 EVA6400/8400 0CxD expansion 7 2 EVA8400 0C9D expansion 8 3 Disk drive status indicator descriptions 27 4 Document conventions 46 6 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 7
to add disk enclosures to an EVA6400/8400 in the main rack, see the HP StorageWorks 6400/8400 Enterprise Virtual Array installation guide or the HP Storage EVA6400/8400 M6412A disk enclosure installation instructions for more information. The installation guide contains cabling diagrams for various - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 8
G2 series rack 252663-xxx 2 (minimum HV) 4 (minimum LV) Power distribution unit (country specific) AG638B 9 M6412-A FC disk enclosure AP712A1 3 HP EVA6400/8400 expansion rack accessory kit, which contains: • HP 5m Multi-mode OM3 LC/LC FC Cable (4) • 4Gb Short Wave FC SFP+ 1 Pack (8) • ROHS - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 9
1. Non-EVA hardware 3. Controllers Figure 1 Rear view of a 2C6D main rack . 2. Disk enclosures 4. Power distribution units HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 9 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 10
1. Disk enclosures 2. Power distribution units Figure 2 Rear view of a 0C6D expansion rack . 0C9D Expansion rack requirements • One existing 2C18D main rack containing a properly wired controller pair and disk enclosures (see Figure 3). The controllers may be above or in the middle of the disk - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 11
1. Disk enclosures 2. Controllers 3. Power distribution units Figure 3 Rear view of a 2C18D main rack . HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 11 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 12
1. Disk enclosures 2. Power distribution units Figure 4 Rear view of a 0C9D expansion rack . 12 Getting started - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 13
information, see the documentation that shipped with your system. Kit contents Check the kit contents to make sure you have the items listed in Figure 5. HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 13 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 14
1. Disk enclosure 5. Rails with -03 brackets 2. Eight disk drive blanks (may come pre-installed in enclosure) 6. Two Fibre Channel copper cables 3. -04 brackets (not used) 7. Two enclosure power cords 4. Pins for round-hole cabinet conversion Figure 5 Kit contents . Converting the rails The - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 15
the rails: • Installing the rails does not require any tools for assembly. • HP recommends you install all the rail kits before installing any other components. • Ensure the or damage if the rack tips over. HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 15 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 16
1. On the rear of the rail, squeeze the scissor latch (1, Figure 7) together to insert the rail and pins through the rack holes (2) until the latch engages. Figure 7 Attaching the rear rail . 2. On the front of the rail, pull the locking latch to release the scissors latch (1, Figure 8) and then - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 17
when removing the bezel covers so as to not break the locking tabs that secure the covers to the enclosure. Figure 10 Remove bezel cover . HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 17 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 18
2. Align the enclosure with the rails and slide it into the rack. Figure 11 Slide disk enclosure onto rails . 3. Continue sliding the enclosure into the rack until the front edge is flush with the front of the rack (1, Figure 12). Tighten the enclosure thumbscrews into the rack (2), taking care to - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 19
bracket forward (2, Figure 15) until the tab engages the slot in the chassis. Tighten the thumbscrew on the bracket. Figure 13 Secure rear of enclosure . HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 19 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 20
6. To install disk drives: a. Insert the disk drive into the drive bay (1, Figure 14) until it clicks, locking the drive. b. Rotate the drive lever to the right (2, Figure 14) until it locks. c. Ensure the drives are installed in the proper sequence, following the numbering scheme in Figure 15. - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 21
within each loop are connected. NOTE: The numbering shown in Figure 17 is for the physical shelf location and may not reflect the I/O module numbering. HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 21 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 22
1. Loop 1 2. Loop 2 Figure 17 0C6D expansion rack for the EVA6400 . 1. Using 0.41m Fiber Channel copper cables, connect the disk enclosures in the first loop: a. Connect P2 (I/O-A) on S-7 to P1 (I/O-A) on S-8. b. Connect P2 (I/O-A) on S-8 to P1 (I/O-A) on S-9. c. Connect P2 (I/O-B) on S-7 to P1 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 23
I/O module numbering. 1. Loop 1 2. Loop 2 3. Loop 3 Figure 18 0C6D expansion rack for the EVA8400 . For six disk enclosures in the expansion rack, complete the following steps: HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 23 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 24
1. Using 0.41m Fiber Channel copper cables, connect the disk enclosures in the first loop: a. Connect P2 (I/O-A) on S-7 to P1 (I/O-A) on S-8. b. Connect P2 (I/O-B) on S-7 to P1 (I/O-B) on S-8. 2. Using 0.41m Fiber Channel copper cables, connect the disk enclosures in the second loop: a. Connect P2 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 25
S-23. b. Connect P2 (I/O-A) on S-23 to P1 (I/O-A) on S-24. c. Connect P2 (I/O-B) on S-22 to P1 (I/O-B) on S-23. d. Connect P2 (I/O-B) on S-23 to P1 (I/O-B) on S-24. HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 25 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 26
3. Using 0.41m Fiber Channel copper cables, connect the disk enclosures in the third loop: a. Connect P2 (I/O-A) on S-25 to P1 (I/O-A) on S-26. b. Connect P2 (I/O-A) on S-26 to P1 (I/O-A) on S-27. c. Connect P2 (I/O-B) on S-25 to P1 (I/O-B) on S-26. d. Connect P2 (I/O-B) on S-26 to P1 (I/O-B) on S- - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 27
each power supply is on and not flashing. If not, diagnose and correct the problem before proceeding with the next steps. Inspect the I/O modules Observe each I/O module Normal operation Off - Firmware malfunction HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 27 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 28
Status indicator Type Fault Description Flashing amber - Warning condition (not visible when solid amber is displaying) Solid amber - Replace component Off - Normal operation Inspect the disk enclosure fan modules Observe the disk enclosure fan modules (1 and 2, Figure 21). Check the fan status - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 29
a fully cabled EVA6400 2C6D main rack configuration. The multi-product rack example assumes that there is non-EVA hardware in the rack above the controllers. HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 29 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 30
steps: a. Verify that the I/O module on the added disk enclosure has been assigned an index number of the next highest enclosure number. b. In HP Command View EVA, verify that the newly added disk enclosure is listed under the array hardware in the Navigation pane and the I/O module displays a good - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 31
Step 2. Figure 23 shows the completed cabling for an EVA6400 2C6D to 0C6D expansion. Figure 23 Complete cabling for an EVA6400 2C6D to 0C6D expansion . HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 31 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 32
General EVA6400 expansion cabling guidelines To adapt the cabling used in Figure 23 to different configurations, follow these cabling guidelines: • Controller A • DP1-A on controller A connects to P1 (I/O-A) on the top disk enclosure in the first loop (expansion rack). • DP2-A on controller A - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 33
steps: a. Verify that the I/O module on the added disk enclosure has been assigned an index number of the next highest enclosure number. b. In HP Command View EVA, verify that the newly added disk enclosure is listed under the array hardware in the Navigation pane and the I/O module displays a good - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 34
3. Unplug DP2-A on controller A from P1 (I/O-A) on disk enclosure 3 (S-3) and: a. Connect DP2-A on controller A to P1 (I/O-A) on disk enclosure 9 (S-9). b. Connect P1 (I/O-A) on disk enclosure 3 (S-3) to P2 (I/O-A) on disk enclosure 10 (S-10). c. Repeat Step 2. 4. Unplug DP3-A on controller A from - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 35
enclosure in the second loop (main rack). • DP3-B on controller A connects to P2 (I/O-B) on the bottom disk enclosure in the third loop (main rack). • Controller B HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 35 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 36
• DP1-A on controller B connects to P2 (I/O-A) on the bottom disk enclosure in the first loop (main rack). • DP2-A on controller B connects to P2 (I/O-A) on the bottom disk enclosure in the second loop (main rack). • DP3-A on controller B connects to P2 (I/O-A) on the bottom disk enclosure in the - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 37
the EVA8400 0C9D expansion rack, there are three disk enclosures per loop. Figure 27 shows the loop 1 connections between the main rack and expansion rack. HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 37 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 38
steps: a. Verify that the I/O modules on the added disk enclosure has been assigned an index number of the next higher enclosure number. b. In HP Command View EVA, verify that the newly added disk enclosure is listed under the array hardware in the Navigation pane and the I/O module displays a good - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 39
has been assigned an index number of the next highest enclosure number. b. In HP Command View EVA, verify that the newly added disk enclosure is listed under the array between the main rack and the expansion rack. HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 39 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 40
19). 2. Complete the following verification steps: a. Verify that the I/O module has been assigned an index number of the next highest enclosure number. b. In HP Command View EVA, verify that the newly added disk enclosure is listed under the array hardware in the Navigation pane and the I/O module - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 41
controllers To shut the storage system down, perform the following steps: 1. Start HP Command View EVA. 2. Select the appropriate storage system in the Navigation pane. Shut down. The Shutdown Options window opens. HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 41 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 42
4. Under System Shutdown click Power Down. If you want to delay the initiation of the shutdown, enter the number of minutes in the Shutdown delay field. The controllers complete an orderly shutdown and then power off. The disk enclosures then power off. Wait for the shutdown to complete. Connecting - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 43
storage system status using HP Command View EVA to ensure everything is operating properly. If any status indicator is not normal, check the log files or contact your HP-authorized service provider for assistance. HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 43 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 44
44 Connecting the main rack to the expansion rack - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 45
Related information Documents The following documents provide related information: • HP StorageWorks 6400/8400 Enterprise Virtual Array user guide • HP StorageWorks EVA6400/8400 M6412A disk enclosure installation instructions You can find these documents on the Storage Access Workbench (SAW) website - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 46
, see the following HP websites: • HP: http://www.hp.com • HP Storage: http://www.hp.com/go/storage • HP Partner Locator: http://www.hp.com/service_locator • HP Software Downloads: http://www.hp.com/support/manuals • HP Software Depot: http://h20293.www2.hp.com • HP Single Point of Connectivity - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 47
loss, data corruption, or damage to hardware or software. An alert that calls attention to additional or CSR, contact your local service provider, or see the CSR website: http://www.hp.com/go/selfrepair This . HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack reference guide 47 - HP 6400/8400 | HP StorageWorks 6400/8400 Enterprise Virtual Array expansion rack - Page 48
48 Support and other resources
HP StorageWorks 6400/8400 Enterprise
Virtual Array expansion rack reference guide
This guide describes how to add an expansion rack to an EVA6400/8400 main rack and is intended for
HP-authorized service personnel only.
Part number: 5697-8184
First edition: September 2009