HP 8/20q HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Simple Network - Page 143

Module table

Page 143 highlights

Access Read-write Status Current Return value The WWN of the switch; for example, 10 00 00 C0 DD 00 71 C9. Writes are not supported. fcFeModuleCapacity (1.3.6.1.2.1.75.1.1.3) The maximum number of modules in the Fabric Element, regardless of their current state. Syntax FcFeModuleCapacity Access Read-only Status Current Return value The total number of switches in the fabric if the ProxyEnable setting is enabled on the out-of-band switch. If the ProxyEnable setting is disabled on the out-of-band switch, the return value is 1. Module table The objects described in this section are in table format, indexed by switch. An example of how to access one of these objects is: snmpget localhost public fcFeModuleDescr.1. This table contains one entry for each module. fcFeModuleDescr (1.3.6.1.2.1.75.1.1.4.1.2) A textual description of the module. This value should include the full name and version identification of the module. Syntax SnmpAdminString Access Read-only Status Current Return value A configuration description of the module table entry. The value for the 8/20q FC switch is HP StorageWorks 8/20q Fibre Channel Switch. The value for the SN600 FC switch is either HP StorageWorks SN6000 Stackable Dual Power Supply Fibre Channel Switch or HP StorageWorks SN6000 Stackable Single Power Supply Fibre Channel Switch. fcFeModuleObjectID (1.3.6.1.2.1.75.1.1.4.1.3) The vendor's authoritative identification of the module. This value may be allocated within the SMI enterprises subtree (1.3.6.1.4.1). The value provides a means for determining what kind of module is being managed. For example, this object could take the value 1.3.6.1.4.1.99649.3.9 if vendor Neufe Inc. was assigned the subtree 1.3.6.1.4.1.99649 and had assigned the identifier 1.3.6.1.4.1.99649.3.9 to its FeFiFo-16 PlugInCard. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Simple Network Management Protocol Reference Guide 143

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188

HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Simple Network Management Protocol Reference Guide
143
Access
Read-write
Status
Current
Return value
The WWN of the switch; for example,
10 00 00 C0 DD 00 71 C9
. Writes are not supported.
fcFeModuleCapacity (1.3.6.1.2.1.75.1.1.3)
The maximum number of modules in the Fabric Element, regardless of their current state.
Syntax
FcFeModuleCapacity
Access
Read-only
Status
Current
Return value
The total number of switches in the fabric if the
ProxyEnable
setting is enabled on the out-of-band
switch. If the
ProxyEnable
setting is disabled on the out-of-band switch, the return value is
1
.
Module table
The objects described in this section are in table format, indexed by switch. An example of how to access
one of these objects is:
snmpget localhost public fcFeModuleDescr.1
. This table contains one
entry for each module.
fcFeModuleDescr (1.3.6.1.2.1.75.1.1.4.1.2)
A textual description of the module. This value should include the full name and version identification of the
module.
Syntax
SnmpAdminString
Access
Read-only
Status
Current
Return value
A configuration description of the module table entry. The value for the
8/20q FC switch is HP
StorageWorks 8/20q Fibre Channel Switch
. The value for the SN600 FC switch is either
HP
StorageWorks SN6000 Stackable Dual Power Supply Fibre Channel Switch
or
HP
StorageWorks SN6000 Stackable Single Power Supply Fibre Channel Switch
.
fcFeModuleObjectID (1.3.6.1.2.1.75.1.1.4.1.3)
The vendor's authoritative identification of the module. This value may be allocated within the SMI
enterprises subtree (
1.3.6.1.4.1
). The value provides a means for determining what kind of module is
being managed.
For example, this object could take the value
1.3.6.1.4.1.99649.3.9
if vendor
Neufe Inc.
was
assigned the subtree
1.3.6.1.4.1.99649
and had assigned the identifier
1.3.6.1.4.1.99649.3.9
to its
FeFiFo-16 PlugInCard
.