HP 8/20q HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Simple Network - Page 72

connUnitStatus 1.3.6.1.3.94.1.6.1.6, connUnitProduct 1.3.6.1.3.94.1.6.1.7

Page 72 highlights

Access Read-only Status Mandatory Return value See Table 4 for switch operational states. Table 4 Switch operational states Switch state online offline diagnostics other unknown Return state online(2) offline(3) offline(3) (1) connUnitStatus (1.3.6.1.3.94.1.6.1.6) Overall status of the connectivity unit. The goal of this object is to be the single poll point to check to the status of the connUnit. If there is any other component that has warning, then this should be set to warning. Any of these values may occur with any of the connUnitState values. Syntax INTEGER Access Read-only Status Mandatory Return value See Table 5 for connectivity unit return values. Return value is OK(3), unless one or more of the following occurs. Table 5 Connectivity unit return values Return value Status that can cause return value warning(4) • One or more cooling fan failed • Temperature status = Warm • Any port is down • Switch offline or in diagnostics mode failed(5) • Power supply is reporting bad and/or not installed • All cooling fans failed • Temperature status = Overheating • POST failed connUnitProduct (1.3.6.1.3.94.1.6.1.7) The SML attribute Config.Snmp.SysDescr. This is the system description shown on the show version Telnet screen. It can also be read on the show setup snmp screen and written using the set setup snmp Telnet screen. 72 Fibre Alliance MIB Objects

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188

72
Fibre Alliance MIB Objects
Access
Read-only
Status
Mandatory
Return value
See
Table 4
for switch operational states.
connUnitStatus (1.3.6.1.3.94.1.6.1.6)
Overall status of the connectivity unit. The goal of this object is to be the single poll point to check to the
status of the
connUnit
. If there is any other component that has warning, then this should be set to
warning. Any of these values may occur with any of the c
onnUnitState
values.
Syntax
INTEGER
Access
Read-only
Status
Mandatory
Return value
See
Table 5
for connectivity unit return values. Return value is
OK(3)
, unless one or more of the
following occurs.
connUnitProduct (1.3.6.1.3.94.1.6.1.7)
The SML attribute
Config.Snmp.SysDescr
. This is the system description shown on the
show
version
Telnet screen. It can also be read on the
show setup snmp
screen and written using the
set
setup snmp
Telnet screen.
Table 4
Switch operational states
Switch state
Return state
online
online(2)
offline
offline(3)
diagnostics
offline(3)
other unknown
(1)
Table 5
Connectivity unit return values
Return value
Status that can cause return value
warning(4)
One or more cooling fan failed
Temperature status =
Warm
Any port is down
Switch offline or in diagnostics mode
failed(5)
Power supply is reporting bad and/or not installed
All cooling fans failed
Temperature status =
Overheating
POST failed