HP 8/80 Access Gateway Administrator's Guide (53-1001760-01, June 2010) - Page 83

SAN Configuration with Access Gateway, In this Connectivity of multiple devices overview

Page 83 highlights

Chapter SAN Configuration with Access Gateway 4 In this chapter •Connectivity of multiple devices overview 63 •Direct target attachment 63 •Target aggregation 64 •Access Gateway cascading 64 •Fabric and Edge switch configuration 65 •Connectivity to Cisco Fabrics 67 •Rejoining Fabric OS switches to a fabric 67 Connectivity of multiple devices overview This chapter describes how to connect multiple devices to a switch in Access Gateway (AG) mode, and discusses Edge switch compatibility, target aggregation, direct target attachment, port requirements, NPIV HBA, and interoperability. AG does not support daisy chaining when two AG devices are connected to each other in a loop configuration. Switches in AG mode can connect to third-party fabrics with the following firmware versions: • M-EOSc v9.6.2 or later and M-EOSn v9.6 or later. • Cisco MDS Switches with SAN OS v3.0(1). • Loop devices and FICON channels/control unit connectivity are not supported. • When a switch is in AG mode, it can be connected to NPIV-enabled HBAs, or F_Ports that are NPIV-aware. Access Gateway supports NPIV industry standards per FC-LS-2 v1.4. Direct target attachment FCP targets can directly connect to an AG module instead of through a fabric connection. Even though target devices can directly be connected to AG ports we recommend that target devices be connected to the core Fabric. Follow the "Considerations" below when connecting target devices directly to an AG. Considerations • Direct Target attachment to AG is only supported if the AG module is also connected to a core fabric. A switch module running in AG mode does not provide Name Services on its own, and routing to the target devices will need to be established by the core fabric. • Hosts and targets can not be mapped to the same N-port. Access Gateway Administrator's Guide 63 53-1001760-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

Access Gateway Administrator’s Guide
63
53-1001760-01
Chapter
4
SAN Configuration with Access Gateway
In this chapter
Connectivity of multiple devices overview . . . . . . . . . . . . . . . . . . . . . . . . . . .
63
Direct target attachment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
63
Target aggregation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
64
Access Gateway cascading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
64
Fabric and Edge switch configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
65
Connectivity to Cisco Fabrics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
67
Rejoining Fabric OS switches to a fabric . . . . . . . . . . . . . . . . . . . . . . . . . . . .
67
Connectivity of multiple devices overview
This chapter describes how to connect multiple devices to a switch in Access Gateway (AG) mode,
and discusses Edge switch compatibility, target aggregation, direct target attachment, port
requirements, NPIV HBA, and interoperability. AG does not support daisy chaining when two AG
devices are connected to each other in a loop configuration. Switches in AG mode can connect to
third-party fabrics with the following firmware versions:
M-EOSc v9.6.2 or later and M-EOSn v9.6 or later.
Cisco MDS Switches with SAN OS v3.0(1).
Loop devices and FICON channels/control unit connectivity are not supported.
When a switch is in AG mode, it can be connected to NPIV-enabled HBAs, or F_Ports that are
NPIV-aware. Access Gateway supports NPIV industry standards per FC-LS-2 v1.4.
Direct target attachment
FCP targets can directly connect to an AG module instead of through a fabric connection.
Even though target devices can directly be connected to AG ports we recommend that target
devices be connected to the core Fabric. Follow the
“Considerations”
below when connecting target
devices directly to an AG.
Considerations
Direct Target attachment to AG is only supported if the AG module is also connected to a core
fabric.
A switch module running in AG mode does not provide Name Services on its own, and
routing to the target devices will need to be established by the core fabric.
Hosts and targets can not be mapped to the same N-port.