HP AH226A HP 8 Internal Port SAS Controller and HP Multi-Port Internal SAS Con - Page 14

Completing the Controller Replacement, Reconnect the peripheral devices. - board

Page 14 highlights

3. Label the connectors to the internal drive bays. The connector closest to the mounting bracket is Port 1, and the connector closest to the interior of the server is Port 2. 4. Disconnect the cables from the PCI-X card. 5. Depending on the server model, remove the retaining screw or open the expansion slot latch that secures the PCI-X card. 6. Remove the card. 7. Insert the new card into the slot, and press it firmly into place. The contacts on the adapter edge should be fully seated in the system board connector. 8. Depending on the server model, secure the adapter by replacing the retaining screw or by closing the slot latch. 9. Reconnect the cables to the internal drive bays. Completing the Controller Replacement To complete the replacement and boot the server, follow these steps: 1. Verify that all cables are routed correctly and are not restricting or being pinched by other components. For the correct routing of the cables, see the server documentation. 2. Replace or close the server access panel. 3. Reconnect the peripheral devices. 4. Reconnect the AC power cord. 5. Power on the peripheral devices. 6. Power on the server. 7. Configure the replacement controller. See Chapter 3 (page 15). 8. Update the adapter firmware, if necessary. 14 Replacing a Controller

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

3.
Label the connectors to the internal drive bays. The connector closest to the mounting bracket
is Port 1, and the connector closest to the interior of the server is Port 2.
4.
Disconnect the cables from the PCI-X card.
5.
Depending on the server model, remove the retaining screw or open the expansion slot latch
that secures the PCI-X card.
6.
Remove the card.
7.
Insert the new card into the slot, and press it firmly into place. The contacts on the adapter
edge should be fully seated in the system board connector.
8.
Depending on the server model, secure the adapter by replacing the retaining screw or by
closing the slot latch.
9.
Reconnect the cables to the internal drive bays.
Completing the Controller Replacement
To complete the replacement and boot the server, follow these steps:
1.
Verify that all cables are routed correctly and are not restricting or being pinched by other
components. For the correct routing of the cables, see the server documentation.
2.
Replace or close the server access panel.
3.
Reconnect the peripheral devices.
4.
Reconnect the AC power cord.
5.
Power on the peripheral devices.
6.
Power on the server.
7.
Configure the replacement controller.
See
Chapter 3 (page 15)
.
8.
Update the adapter firmware, if necessary.