HP AH226A HP 8 Internal Port SAS Controller and HP Multi-Port Internal SAS Con - Page 30

SMP Response Index Does Not Exist - 0x040, SMP Response Function Failed - 0x080

Page 30 highlights

Discovery Status Device Identifier Scan Order Device Information SAS Address Link Error Settings Link Error Count Threshold Count Threshold Time 30 Configuring the Controller Offline A 32 bit hexadecimal that indicates the discovery status for the PHY or expander. Possible values: • Discovery completed successfully - 0x00000000 • Loop Detected - 0x00000001 • Unaddressable device exists- 0x00000002 • Multiple Ports - 0x00000004 • Expander Error - 0x00000008 • SMP Timeout - 0x00000010 • Out of route entries - 0x00000020 • SMP Response Index Does Not Exist - 0x00000040 • SMP Response Function Failed - 0x00000080 • SMP CRC error - 0x00000100 Indicates the ASCII device identifier string extracted from the device's inquiry data. Indicates the scan order for this device. This is equivalent to the SCSI ID value in parallel SCSI configurations. Indicates whether a device is SAS. Indicates the SAS address of the device. Invalid DWORDs Number of invalid DWORDs received outside of PHY reset sequences since the last PHY link error reset. Loss of DWORD Sync Number of times that DWORD synchronization was lost and the link reset sequence occurred since the last PHY link error reset. Running Disparity Errors Number of dwords with running disparity errors that have been received outside PHY reset sequences since the last PHY link error reset. PHY Reset Errors Number of times the PHY reset sequence has failed since the last PHY link error reset. Error counts stop when they reach the maximum value. Actual link error count values since the last PHY Link Error Reset. a Link error count threshold values. When a link error count exceeds the threshold count within the threshold time, the MPT firmware may reduce the link rate. You can modify the threshold values on the Advanced Adapter Properties screen. Time, in seconds, over which to apply Threshold Count. When a link error count exceeds the threshold count within the threshold time, the MPT firmware may reduce the link rate. You can modify the threshold values on the Advanced Adapter Properties screen.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

Discovery Status
A 32 bit hexadecimal that indicates the discovery status for the
PHY or expander. Possible values:
Discovery completed successfully - 0x00000000
Loop Detected - 0x00000001
Unaddressable device exists- 0x00000002
Multiple Ports - 0x00000004
Expander Error - 0x00000008
SMP Timeout - 0x00000010
Out of route entries - 0x00000020
SMP Response Index Does Not Exist - 0x00000040
SMP Response Function Failed - 0x00000080
SMP CRC error - 0x00000100
Device Identifier
Indicates the ASCII device identifier string extracted from the
device's inquiry data.
Scan Order
Indicates the scan order for this device. This is equivalent to the
SCSI ID value in parallel SCSI configurations.
Device Information
Indicates whether a device is SAS.
SAS Address
Indicates the SAS address of the device.
Link Error Settings
Number of invalid
DWORDs received outside
Invalid DWORDs
of PHY reset sequences
since the last PHY link error
reset.
Loss of DWORD Sync
Number of times that
DWORD synchronization
was lost and the link reset
sequence occurred since the
last PHY link error reset.
Running Disparity Errors
Number of dwords with
running disparity errors
that have been received
outside PHY reset
sequences since the last
PHY link error reset.
PHY Reset Errors
Number of times the PHY
reset sequence has failed
since the last PHY link error
reset.
Error counts stop when they reach the maximum value.
Link Error Count
Actual link error count values since the last PHY Link Error Reset.
a
Threshold Count
Link error count threshold values. When a link error count exceeds
the threshold count within the threshold time, the MPT firmware
may reduce the link rate. You can modify the threshold values on
the Advanced Adapter Properties screen.
Threshold Time
Time, in seconds, over which to apply Threshold Count. When a
link error count exceeds the threshold count within the threshold
time, the MPT firmware may reduce the link rate. You can modify
the threshold values on the Advanced Adapter Properties screen.
30