HP AP775A Cisco Nexus 5000 Series Hardware Installation Guide, Cisco NX-OS Rel - Page 39

Fan Module, Blank Power Supply Filler Panel, Table 1-5

Page 39 highlights

Chapter 1 Product Overview Nexus 5010 Switch Send documentation comments to [email protected] Table 1-5 Power Supply LED Descriptions (continued) Power Supply Condition Power LED Status Power supply warning events where the power supply Off continues to operate. These events include high temperature, high power, and slow fan. AC present, 3.3 voltage standby (VSB) on, and the power 1 Hz blinking supply unit is off. Power supply on and OK. On Fail LED Status 1 Hz Blinking Off Off If one power supply is installed in the chassis, but the other power supply slot is empty, a blank filler panel should be used to cover the empty slot. Figure 1-31 shows a blank power supply filler panel. Figure 1-31 Blank Power Supply Filler Panel 186854 Fan Module The Cisco Nexus 5010 switch has slots for two fans modules. Each fan module houses six fans. The combination of 6-fans per module and 2-modules provides the switch with a total of 12-fans.Figure 1-32 shows the fan module. OL-15902-01 Cisco Nexus 5000 Series Hardware Installation Guide 1-25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

Send documentation comments to [email protected]
1-25
Cisco Nexus 5000 Series Hardware Installation Guide
OL-15902-01
Chapter 1
Product Overview
Nexus 5010 Switch
If one power supply is installed in the chassis, but the other power supply slot is empty, a blank filler
panel should be used to cover the empty slot.
Figure 1-31
shows a blank power supply filler panel.
Figure 1-31
Blank Power Supply Filler Panel
Fan Module
The Cisco Nexus 5010 switch has slots for two fans modules. Each fan module houses six fans. The
combination of 6-fans per module and 2-modules provides the switch with a total of 12-fans.
Figure 1-32
shows the fan module.
Power supply warning events where the power supply
continues to operate. These events include high
temperature, high power, and slow fan.
Off
1 Hz Blinking
AC present, 3.3 voltage standby (VSB) on, and the power
supply unit is off.
1 Hz blinking
Off
Power supply on and OK.
On
Off
Table 1-5
Power Supply LED Descriptions (continued)
Power Supply Condition
Power LED Status
Fail LED Status