HP Cisco MDS 9020 HP StorageWorks C-Series iSCSI Configuration Guide (AA-RW7PE - Page 45

Configuring p-Class Blade GbE2 server enclosure interconnects, Disabling a port

Page 45 highlights

Figure 41 Disabling a port 5. Click Submit (Figure 41). Verifying VLAN settings After disabling the XConnects, verify that each port used in the iSCSI setup is enabled and is part of the same VLAN. To verify: 1. From Windows Start, select Run. 2. Enter "telnet" in the Run dialog box. 3. Log in to Interconnect A or B and run the command "show vlan" (Figure 42). NOTE: All ports are members of the same VLAN and are in VLAN 1 by default. Verify the VLAN settings for Interconnects A and B. Figure 42 Interconnect telnet session Configuring p-Class Blade GbE2 server enclosure interconnects This section describes a configuration example using GbE2 interconnects. For details on the configuration or installation of the interconnects, see the specific Blade server documentation. Setup Using the setup instructions in the HP ProLiant BL p-Class GbE2 Interconnect Switch Application Guide, enable the Browser-Based Interface (BBI). Access the configuration management and operation features of the switch through the BBI and your Web browser. Use the web interface to disable the cross connection C-Series iSCSI 45

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49

Figure 41 Disabling a port
5.
Click Submit (
Figure 41
).
Verifying VLAN settings
After disabling the XConnects, verify that each port used in the iSCSI setup is enabled and is part
of the same VLAN. To verify:
1.
From Windows
Start
, select
Run
.
2.
Enter “telnet” in the Run dialog box.
3.
Log in to Interconnect A or B and run the command “show vlan” (
Figure 42
).
NOTE:
All ports are members of the same VLAN and are in VLAN 1 by default.
Verify the VLAN settings for Interconnects A and B.
Figure 42 Interconnect telnet session
Con
guring p-Class Blade GbE2 server enclosure interconnects
This section describes a con
guration example using GbE2 interconnects. For details on the con
guration
or installation of the interconnects, see the speci
c Blade server documentation.
Setup
Using the setup instructions in the
HP ProLiant BL p-Class GbE2 Interconnect Switch Application Guide
,
enable the Browser-Based Interface (BBI). Access the con
guration management and operation features of
the switch through the BBI and your Web browser. Use the web interface to disable the cross connection
C-Series iSCSI
45