HP Cisco MDS 9216A Cisco MDS 9000 Family System Messages Reference (OL-15956-0 - Page 468
SCSI target process persistent storage service PSS set runtime max key failed because
View all HP Cisco MDS 9216A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 468 highlights
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family Send documentation comments to [email protected] Error Message VHBAD-3-PSS_DELETE_FAIL: pss delete runtime entry key:[hex] failed due to error: [hex]. Explanation SCSI target process persistent storage service (PSS) delete runtime entry key failed because of the error shown in the error message. Recommended Action Enter the show flash CLI command or use a similar Fabric Manager/Device Manager procedure to collect more information. See PSS system error codes for the reason. Introduced Cisco MDS SAN-OS Release 1.2(2a). Error Message VHBAD-3-PSS_MAX_KEY_FAIL: pss set runtime max key failed due to error: [hex]. Explanation SCSI target process persistent storage service (PSS) set runtime max key failed because of the error shown in the error message. No SCSI discovery can be performed. Recommended Action Enter the show flash CLI command or use a similar Fabric Manager/Device Manager procedure to collect more information. See PSS system error codes for reason. Introduced Cisco MDS SAN-OS Release 1.2(2a). Error Message VHBAD-3-PSS_MAX_VALUE_FAIL: pss set runtime max value failed due to error: [hex]. Explanation SCSI target process persistent storage service (PSS) set runtime max value failed because of the error shown in the error message. No SCSI discovery can be performed. Recommended Action Enter the show flash CLI command or use a similar Fabric Manager/Device Manager procedure to collect more information. See PSS system error codes for reason. Introduced Cisco MDS SAN-OS Release 1.2(2a). Error Message VHBAD-3-PSS_OPEN_FAIL: pss open runtime database failed due to error: [hex]. Explanation SCSI target process persistent storage service (PSS) open runtime database failed because of the error shown in the error message. No SCSI discovery can be performed. Recommended Action Enter the show flash CLI command or use a similar Fabric Manager/Device Manager procedure to collect more information. See PSS system error codes for the reason. Introduced Cisco MDS SAN-OS Release 1.2(2a). Error Message VHBAD-3-PSS_RELOAD_FAIL: pss reload runtime database failed due to error: [hex]. Explanation SCSI target process persistent storage service (PSS) reload runtime database failed because of the error shown in the error message. Recommended Action Enter the show flash CLI command or use a similar Fabric Manager/Device Manager procedure to collect more information. See PSS system error codes for reason. Introduced Cisco MDS SAN-OS Release 1.2(2a). 2-432 Cisco MDS 9000 Family System Messages Reference OL-15956-01