Caveats Send documentation comments to [email protected] Symptom: Following a reboot of an MDS 9513 switch running Cisco SAN-OS Release 3.3(2), both supervisor modules generated core files. The show cores command and the show system reset-reason command displayed the following output: switch# show cores Module-num Process-name ---------- ------------ 8 qos 7 qos PID --15671 4370 Core-create-time Sep 21 22:16 Sep 21 22:17 switch# show system reset-reason ----- reset reason for Supervisor-module 8 (from Supervisor in slot 8) --1) At 517868 usecs after Mon Sep 21 22:12:09 2009 Reason: Reset triggered due to HA policy of Reset Service: Service "qos" Version: 3.3(2) ----- reset reason for Supervisor-module 7 (from Supervisor in slot 7) --1) At 260648 usecs after Mon Sep 21 22:12:37 2009 Reason: Reset triggered due to HA policy of Reset Service: Service "qos" Version: 3.3(2) Workaround: This issue is resolved. • CSCtc48338 Symptom: On any of the MDS 9500 Series Director switches that have removable Supervisor 2 modules, a supervisor may reset when any one of the following commands is executed on the switch, or the same information is collected through Cisco Fabric Manager or Device Manager: • show hardware internal mgmt0 stats • show hardware internal eobc stats • show tech • show tech details • show tech-support • tac-pac In a dual supervisor switch, entering one of these commands will force a supervisor switchover. In single supervisor systems, the switch will reload. This issue does not affect switches with a nonremovable Supervisor 2 module, such as the MDS 9222i or MDS 9124. Workaround: This issue is resolved. Open Caveats • CSCsr85709 Symptom: Under certain conditions, the port manager can take a long time to respond to a port configuration, which can trigger a set-port-configuration failure. If this occurs, then the FCIP tunnel will not come up and will stay in a disabled state. Workaround: Enter a shut command, followed by a no shut command on the FCIP interface at either end of the FCIP tunnel. OL-14116-13 Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(4a) 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

Send documentation comments to [email protected]
31
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(4a)
OL-14116-13
Caveats
Symptom
: Following a reboot of an MDS 9513 switch running Cisco SAN-OS Release 3.3(2), both
supervisor modules generated core files. The
show cores
command and the
show system
reset-reason
command displayed the following output:
switch# show cores
Module-num
Process-name
PID
Core-create-time
----------
------------
---
----------------
8
qos
15671
Sep 21 22:16
7
qos
4370
Sep 21 22:17
switch# show system reset-reason
----- reset reason for Supervisor-module 8 (from Supervisor in slot 8) ---
1) At 517868 usecs after Mon Sep 21 22:12:09 2009
Reason: Reset triggered due to HA policy of Reset
Service: Service "qos"
Version: 3.3(2)
----- reset reason for Supervisor-module 7 (from Supervisor in slot 7) ---
1) At 260648 usecs after Mon Sep 21 22:12:37 2009
Reason: Reset triggered due to HA policy of Reset
Service: Service "qos"
Version: 3.3(2)
Workaround
: This issue is resolved.
CSCtc48338
Symptom
: On any of the MDS 9500 Series Director switches that have removable Supervisor 2
modules, a supervisor may reset when any one of the following commands is executed on the switch,
or the same information is collected through Cisco Fabric Manager or Device Manager:
show hardware internal mgmt0 stats
show hardware internal eobc stats
show tech
show tech details
show tech-support
tac-pac
In a dual supervisor switch, entering one of these commands will force a supervisor switchover. In
single supervisor systems, the switch will reload.
This issue does not affect switches with a nonremovable Supervisor 2 module, such as the MDS
9222i or MDS 9124.
Workaround
: This issue is resolved.
Open Caveats
CSCsr85709
Symptom
: Under certain conditions, the port manager can take a long time to respond to a port
configuration, which can trigger a set-port-configuration failure. If this occurs, then the FCIP tunnel
will not come up and will stay in a disabled state.
Workaround
: Enter a
shut
command, followed by a
no shut
command on the FCIP interface at
either end of the FCIP tunnel.