HP DL320 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide
HP DL320 - ProLiant - G3 Manual
UPC - 829160513218
View all HP DL320 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP DL320 manual content summary:
- HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 1
HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide September 2003 (Fourth Edition) Part Number 293164-004 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 2:00 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 2
such products. Nothing herein should be construed as constituting an additional warranty. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide September 2003 (Fourth Edition) Part Number 293164-004 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22 - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 3
2-15 Hard Drives ...2-16 Single Channel Wide Ultra3 SCSI Controller Module 2-19 Optical Device/Diskette Drive Assembly Backplane 2-20 User Interface Board ...2-21 PCI Riser Board Assembly...2-22 Expansion Board...2-23 PCI Card Guide...2-24 Center Wall...2-25 HP ProLiant DL320 Generation 2 Server - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 4
ATA/100 Controller ...5-8 Optional Hard Drives...5-9 Ultra3 SCSI Hard Drives...5-9 ATA Hard Drives ...5-10 Integrated NC7760 Gigabit Server Auto-Switching Network Interface Controller (NIC 5-11 Index iv HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 5
the power supplies. • Do not disable the power cord grounding plug. The grounding plug is an important safety feature. • Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide v HP - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 6
operation, plug the AC power cord into a properly grounded AC outlet only. NOTE: Any indications of component replacement or printed wiring board modifications may void any warranty. vi HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 7
In Canada, call 1-800-263-5868. For HP technical support: • In the United States and Canada, call 1-800-652-6672. • Outside the United States and Canada, refer to www.hp.com HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide vii HP CONFIDENTIAL Codename: Moonstar 306 Part Number - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 8
for all referenced spare parts. Mechanical Parts Exploded View 1 18c 2 Figure 1-1: Mechanical parts exploded view 18a 17b 17a 18b HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 1-1 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:45 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 9
Illustrated Parts Catalog System Components Exploded View Figure 1-2: System components exploded view 1-2 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:45 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 10
001 293365-001 293366-001 293367-001 207725-001 336782-001 293368-001 293618-001 293370-001 326509-001 344041-001 293377-001 300691-001 300699-001 300700-001 300701-001 293371-001 269046-001 287685-001 345567-001 continued HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 1-3 HP - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 11
* * Not shown Spare Part Number 234556-001 293373-001 293372-001 293374-001 293375-001 173845-001 207732-001 293376-001 232386-001 177852-001 177853-001 177854-001 1-4 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164 - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 12
. • Avoid touching pins, leads, or circuitry. • Always place drives with the Printed Circuit Board (PCB) assembly-side down. • Use conductive field service tools. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-1 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 13
ROM or DVD-ROM CLASS 1 LASER PRODUCT drive. This label indicates that the product is classified server in a telco rack, make certain that the rack frame is adequately secured to the building structure at the top and bottom. 2-2 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 14
key • Bezel blank • Optical device/diskette drive assembly • Bezel • Hard drives - ATA hard drives - SCSI hard drives • Single Channel Wide Ultra3 SCSI controller module HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-3 HP CONFIDENTIAL Codename: Moonstar 306 Part Number - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 15
device terminated SCSI cable - ATA cables - Optical device/diskette drive assembly cable • Power supply • Battery • Memory modules • Processor • System board 2-4 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 16
users may use the Power Down Manager to power down the server. For information on this system utility, refer to the NTREADME.HLP file on Diskette 1 of the NT Software Support Diskettes. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-5 HP CONFIDENTIAL Codename: Moonstar 306 - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 17
auxiliary power is still connected to the PCI expansion slot and may damage the card. CAUTION: Electrostatic discharge can damage electronic components. Ensure proper grounding before beginning any installation procedure. 2-6 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 18
Procedures To remove the access panel: 1. Power down the server. See "Powering Down the Server" in this chapter. 2. Press and access panel, reverse steps 1 through 3. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-7 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164 - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 19
the optical device/diskette drive assembly. To remove the shipping/ejector key: 1. Power down the server. See "Powering Down the Server" in this chapter. the shipping/ejector key. 2-8 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 20
into the empty bay until it locks into place. Store the shipping/ejector key in the chassis or other safe location for future use. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-9 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:47 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 21
device/diskette drive assembly: 1. Power down the server. See "Powering Down the Server" in drive assembly or the bezel blank installed. To replace the assembly, slide the assembly into the bay until it is fully seated. 2-10 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 22
device/diskette drive assembly ejection is anticipated, leave the key in the ejector port for easy access, as shown in Figure 2-5. Otherwise, store the shipping/ejector key inside the chassis for future use. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-11 HP CONFIDENTIAL - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 23
Device/Diskette Drive Assembly," or "Bezel Blank" in this chapter. 4. Remove the four screws that secure the bezel to each side of the chassis. Figure 2-6: Removing the bezel screws 2-12 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 24
1 through 7, omitting step 5. When the bottom of the bezel is hooked securely in place, the bezel top snaps into the chassis tabs. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-13 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:47 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 25
to determine how to set the jumpers on the ATA hard drives to Cable-Select mode, if they are not already set in Cable-Select mode. 2-14 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:47 - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 26
. IMPORTANT: Always populate hard drive bays starting with the lowest ATA device number or recommended SCSI ID number. Figure 2-8: ATA device numbers or recommended SCSI ID numbers HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-15 HP CONFIDENTIAL Codename: Moonstar 306 - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 27
ATA hard drives Table 2-2: Hard Drive Cable Removal Sequence Item 1 2 3 4 Description ATA secondary controller connector Secondary drive cable ATA primary controller connector Primary drive cable 2-16 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 28
(1). b. Slide the tray toward the rear of the server and lift the tray out of the chassis (2). Figure 2-11: Removing the hard drive tray from the chassis HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-17 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 29
are installed with the data and power connectors along the bottom of the tray, facing away from the front vent holes. Reverse steps 1 through 7 to replace the hard drive. 2-18 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part Number - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 30
Module To remove the SCSI module: 1. Power down the server. See "Powering Down the Server" in this chapter. 2. Remove the access SCSI module seats securely on the support posts. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-19 HP CONFIDENTIAL Codename: Moonstar 306 Part - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 31
(center wall removed for clarity) Reverse steps 1 through 7 to replace the optical device/diskette drive assembly backplane. 2-20 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:47 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 32
the light pipes. Figure 2-15: Removing the user interface board Reverse steps 1 through 6 to replace the user interface board. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-21 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:47 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 33
remove the PCI riser board assembly: 1. Power down the server. See "Powering Down the Server" in this chapter. 2. Remove the access on the rear of the chassis. 2-22 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164- - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 34
power switch is off, auxiliary power is still connected to the PCI expansion slot and may damage the card. 1. Power down the server. See "Powering Down the Server assembly and access panel. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-23 HP CONFIDENTIAL Codename: Moonstar - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 35
Replacement Procedures PCI Card Guide To remove a PCI card guide: 1. Power down the server. See "Powering Down the Server" in this chapter. guide Reverse steps 1 through 6, omitting step 5, to replace a PCI card guide. 2-24 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 36
Center Wall To remove the center wall: 1. Power down the server. See "Powering Down the Server" in this chapter. 2. Remove the access cables (processor removed for clarity) HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-25 HP CONFIDENTIAL Codename: Moonstar 306 Part Number - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 37
(2). Figure 2-21: Clearing the center wall alignment tab Reverse steps 1 through 8, omitting step 6, to replace the center wall. 2-26 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:47 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 38
Figure 2-22: Locating the system fans Table 2-3: System Fans Item 1 2 3 4 5 Component Fan 1 Fan 2 Fan 3 Fan 4 Power supply fans HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-27 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:47 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 39
from the hard drives (1). 6. Disconnect the SCSI cable from the SCSI module (2). Figure 2-23: Disconnecting the two-device terminated SCSI cable Reverse steps 1 through 6 to replace the two-device terminated SCSI cable. 2-28 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 40
remove the ATA cables: 1. Power down the server. See "Powering Down the Server" in this chapter. 2. hard drive connector (4). Figure 2-24: Disconnecting the ATA cables Reverse steps 1 through 6 to replace the ATA cables. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-29 HP - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 41
Figure 2-25: Disconnecting the optical device/diskette drive assembly cable Reverse steps 1 through 6 to replace the optical device/diskette drive assembly cable. 2-30 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164 - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 42
the hard drive power cables from the hard drives (1). 6. Disconnect the power supply cable from the power supply server (4). Figure 2-26: Removing the power supply Reverse steps 1 through 8 to replace the power supply. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-31 HP - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 43
of BIOS settings occurs when the battery is removed. BIOS settings must configure the system after replacing the battery. Refer to the HP Servers Troubleshooting Guide or setup and installation guide for more information. 2-32 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 44
Replacement Procedures To remove the battery: 1. Power down the server. See "Powering Down the Server" in this chapter. 2. Remove the is installed with the positive side up. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-33 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 45
Removal and Replacement Procedures Memory Modules The server supports up to four PC2100 DDR ECC socket 2 DIMM socket 3 DIMM socket 4 (populated) 2-34 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 46
DDR ECC memory DIMMs. The DDR memory DIMMs must support CAS memory module (2). Figure 2-29: Removing a DIMM from a DIMM socket 5. Align the key slot in the bottom edge of the DIMM with the tab in the expansion socket. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-35 HP - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 47
CAUTION: Use only HP supplied DIMMs. DIMMs from other sources can adversely affect data integrity. 7. Press down firmly on the DIMM while pushing the latches inward until the latches snap into place. 2-36 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 48
the processor. To remove the processor: 1. Power down the server. See "Powering Down the Server" in this chapter. 2. Remove the access panel the system from functioning properly. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-37 HP CONFIDENTIAL Codename: Moonstar 306 Part - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 49
side) 5. Remove the heatsink from the top of the processor. Figure 2-33: Removing the heatsink (both retaining clips disengaged) 2-38 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:47 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 50
CAUTION: Always use a new heatsink when replacing processors. Failure to use new components may result in damage to the processor. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-39 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:47 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 51
. 10. Disconnect the SCSI or ATA drive cables from the hard drives. See "Hard Drives" in this chapter. 11. Remove the system battery. See "Battery" in this chapter. 2-40 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164 - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 52
keyhole locations, 1 through 6, on the system board. Figure 2-35: Identifying system board alignment keys and keyhole locations HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-41 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:47 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 53
the Enter key to clear the warning. 3. Enter the serial number and press the Enter key. 4. Press the Escape key to close the menu. 2-42 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:47 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 54
5. Press the Escape key to exit RBSU. 6. Press the F10 key to confirm exiting RBSU. The server will automatically reboot. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-43 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:47 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 55
must be accessed when a system configuration error is detected during Power-On Self-Test (POST). For a complete list of POST error messages, refer to the HP Servers Troubleshooting Guide. Diagnostics software is also available on the SmartStart and Software Support CD. Run the Inspect Utility from - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 56
provided in the Server Setup and Management pack. The IML requires operating system-dependent drivers. Refer to the SmartStart and Software Support CD for instructions on installing the appropriate drivers. continued 3-2 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 57
is a function of the combined hardware and software system through the RBSU. Set the ASR to enable. Run this utility from the ROMPaq diskette after powering up the system unit. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 3-3 - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 58
, and LED indicator locations on the front panel, rear panel, system board, and hard drives for the HP ProLiant DL320 Generation 2 server. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 4-1 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 59
Power connector Expansion slot RJ-45 Fast Ethernet connector for NIC 2 RJ-45 Fast Ethernet connector for NIC 1 (supports PXE) Mouse connector Serial connector Video connector Keyboard connector USB 1 connector USB 2 connector 4-2 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 60
4-2: Expansion slot connector Table 4-2: Expansion Slot Item 1 2 Description Expansion board slot cover 64-bit 33-MHz PCI slot HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 4-3 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:54 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 61
(populated) Fan 3 connector 13 Fan 4 connector 14 Processor power connector 15 DIMM socket 1 16 DIMM socket 2 17 DIMM socket 3 18 DIMM socket 4 (populated) 4-4 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 62
Figure 4-4: System switches Table 4-4: System Switches Item 1 2 Description System configuration switch (SW1) Non-maskable interrupt (NMI) switch HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 4-5 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 63
RBSU will not commit any configuration changes. Open (off) Closed (on) = BIOS will clear CMOS and service emergency that requires a complete data dump in preparation for recovering the system from a catastrophic failure. 4-6 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 64
On = Local management Blinking = Remote management Off = Deactivated On = Link Off = No link Blinking = Activity continued HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 4-7 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:54 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 65
Degraded Red = Critical error On = Activity Off = No activity Green = Power on Amber = Standby Off = Power off On = Activity Off = No activity 4-8 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22 - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 66
= Activity On = Link Off = No link Blinking = Activity On = Local management Blinking = Remote management Off = Deactivated HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 4-9 HP CONFIDENTIAL Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:54 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 67
is not illuminated, either the power cord is not connected or the power supply has failed. Figure 4-7: Power status LEDs Item 1 2 Description Power supply Auxiliary power supply 4-10 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 306 Part - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 68
and performance specifications for HP ProLiant DL320 Generation 2 server components and optional hardware, including: • System unit • Power supply • Memory • CD-ROM/diskette drive assembly - Low-profile 1.44-MB diskette drive - Low-profile IDE CD-ROM drive • DVD-ROM/diskette drive assembly - Low - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 69
Specifications Item Description Height 4.19 cm (1.65 in) Depth 65.45 cm (25.75 in) Width 42.55 cm (16.75 in) Weight (maximum) 11.81 kg (26 lb) Weight (no drives is 70 kpa. 5-2 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 306 - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 70
The DDR DIMMs must support CAS Latency 2, or greater. They must also contain the mandatory Joint Electronic Device Engineering Council (JEDEC) Serial Presence Detect (SPD). Use HP supplied SDRAM only. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 5-3 HP CONFIDENTIAL Codename - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 71
Drive Table 5-4: Low-Profile 1.44-MB Diskette Drive Specifications Item Size LED (front panel) Read/write capacity per diskette (high/low density) Drives supported Drive height Drive HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 306 Part Number: 293164-004 - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 72
Drive Table 5-5: Low-Profile IDE CD-ROM Drive Specifications Item Applicable disk formats Capacity Block size Dimensions to 118°F) 5% to 90% (10% to 80%) HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 5-5 HP CONFIDENTIAL Codename: MoonStar 306 Part Number: 293164-004 Last - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 73
cm (5.16 in) - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 74
Specifications Item Temperature range (non-condensing) Operating Shipping Relative humidity (non-condensing) Operating Non-operating Maximum drives supported Logical drives supported Simultaneous drive Yes HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 5-7 HP CONFIDENTIAL - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 75
133 MBps UDMA Modes 5/4/3/2/1/0, DMA Modes 2/1/0, PIO Modes 4/3/2/1/0 ATA/100 compatible CRC (Cyclical Redundancy Check) 128 byte 5-8 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1:55 PM - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 76
35° 50° to 95° Specifications 18.2 GB 18,209 MB Third, 2.54 cm (1.0 in) 8.89 cm (3.5 in) Ultra3 SCSI 160 MBps 0.8 ms 7.5 ms 16.0 ms 10,000 rpm 512 35,556,080 10° to 35° 50º to 95° HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 5-9 HP CONFIDENTIAL Codename: MoonStar 306 Part - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 77
Specifications ATA Hard Drives Table 5-10: ATA Hard Drive Specifications Formatted capacity 512 156,301,488 10° to 35° 50º to 95° 5-10 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 306 Part Number: 293164-004 Last Saved On: 9/22/03 1: - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 78
Integrated NC7760 Gigabit Server Auto-Switching Network Interface Controller (NIC) Specifications Item Network Mbps RJ-45 Plug and Play PCI FCC class A HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 5-11 HP CONFIDENTIAL Codename: MoonStar 306 Part Number: 293164-004 Last Saved - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 79
video 4-2 connectors, switches, and LEDs 4-2 country kit, part numbers 1-4 D device numbers ATA 2-15 SCSI 2-15 diagnostic tools 3-1 diagnostics accessing 3-1 locating 3-1 DIMMs HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide Index-1 HP CONFIDENTIAL Codename: MoonStar 306 Part - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 80
Log (IML) 3-2 Integrated Ultra ATA/100 controller, specifications 5-8 IRQ conflict, resolving 3-3 J jumper settings guidelines for ATA hard drives 2-14 Index-2 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 306 Part Number: 293164-004 Last - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 81
2-35 SCSI hard drives 2-15 POST See Power-On Self-Test power connector, location 4-2 LED 4-8 Power On/Off switch 2-6 power status LED 4-10 power supply frequency range 5-3 installing 2-31 part number 1-3 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide Index-3 HP CONFIDENTIAL - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 82
and Software Support CD 2-1 SmartStart CD, description 3-2 specifications ATA hard drives 5-10 CD-ROM drive 5-5 diskette drive 5-4 DVD-ROM drive 5-6 Integrated Ultra ATA/100 controller 5-8 memory 5-3 Index-4 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL - HP DL320 | HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide - Page 83
power supply 5-3 SCSI hard drives 5-9 SCSI module See specifications, location 4-5 Power On/Off 2-6 system configuration switch (SW1), function 4-6 system configuration switch W warranty vi HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide Index-5 HP CONFIDENTIAL Codename:
HP ProLiant DL320 Generation 2 Server
Maintenance and Service Guide
September 2003 (Fourth Edition)
Part Number 293164-004
HP CONFIDENTIAL
Codename: Moonstar 306 Part Number: 293164-004 Last Saved On: 9/22/03 2:00 PM