HP DL320 HP ProLiant DL320 Generation 2 Server Setup and Installation Guide - Page 36

Installing a CD-ROM/diskette or DVD-ROM/diskette Drive Assembly (Optional)

Page 36 highlights

Installing Hardware Options b. To cable a Smart Array Controller expansion board, remove the center wall, connect the SCSI cable and hard drive power cable to the SCSI hard drives, and reinstall the center wall. Be sure the SCSI cable lies flat across the opening in the center wall. IMPORTANT: When connecting the power cable to the hard drives, ensure that the connectors are installed with the red wires facing right (as viewed from the front of the server). Figure 3-11: Smart Array controller cabled to SCSI hard drives c. To cable other expansion boards, refer to the instructions included with the board. 5. Reverse the procedures performed in the "Accessing Internal Server Components" section earlier in this chapter. Installing a CD-ROM/diskette or DVD-ROM/diskette Drive Assembly (Optional) The CD-ROM/diskette drive and the DVD-ROM/diskette drive procedures are the same. HP ProLiant DL320 Generation 2 Server Setup and Installation Guide 3-15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139

Installing Hardware Options
b.
To cable a Smart Array Controller expansion board, remove the center wall,
connect the SCSI cable and hard drive power cable to the SCSI hard drives,
and reinstall the center wall. Be sure the SCSI cable lies flat across the
opening in the center wall.
IMPORTANT:
When connecting the power cable to the hard drives, ensure that the
connectors are installed with the red wires facing right (as viewed from the front of the
server).
Figure 3-11: Smart Array controller cabled to SCSI hard
drives
c.
To cable other expansion boards, refer to the instructions included with the
board.
5.
Reverse the procedures performed in the “Accessing Internal Server
Components” section earlier in this chapter.
Installing a CD-ROM/diskette or DVD-ROM/diskette
Drive Assembly (Optional)
The CD-ROM/diskette drive and the DVD-ROM/diskette drive procedures are the
same.
HP ProLiant DL320 Generation 2 Server Setup and Installation Guide
3-15